Your browser doesn't support javascript.
loading
Standardized processing of MALDI imaging raw data for enhancement of weak analyte signals in mouse models of gastric cancer and Alzheimer's disease.
Schwartz, Matthias; Meyer, Björn; Wirnitzer, Bernhard; Hopf, Carsten.
Afiliação
  • Schwartz M; Center for Applied Research in Biomedical Mass Spectrometry (ABIMAS), Mannheim University of Applied Sciences, Paul-Wittsack-Str. 10, 68163, Mannheim, Germany.
Anal Bioanal Chem ; 407(8): 2255-64, 2015 Mar.
Article em En | MEDLINE | ID: mdl-25542565
ABSTRACT
Conventional mass spectrometry image preprocessing methods used for denoising, such as the Savitzky-Golay smoothing or discrete wavelet transformation, typically do not only remove noise but also weak signals. Recently, memory-efficient principal component analysis (PCA) in conjunction with random projections (RP) has been proposed for reversible compression and analysis of large mass spectrometry imaging datasets. It considers single-pixel spectra in their local context and consequently offers the prospect of using information from the spectra of adjacent pixels for denoising or signal enhancement. However, little systematic analysis of key RP-PCA parameters has been reported so far, and the utility and validity of this method for context-dependent enhancement of known medically or pharmacologically relevant weak analyte signals in linear-mode matrix-assisted laser desorption/ionization (MALDI) mass spectra has not been explored yet. Here, we investigate MALDI imaging datasets from mouse models of Alzheimer's disease and gastric cancer to systematically assess the importance of selecting the right number of random projections k and of principal components (PCs) L for reconstructing reproducibly denoised images after compression. We provide detailed quantitative data for comparison of RP-PCA-denoising with the Savitzky-Golay and wavelet-based denoising in these mouse models as a resource for the mass spectrometry imaging community. Most importantly, we demonstrate that RP-PCA preprocessing can enhance signals of low-intensity amyloidpeptide isoforms such as Aß1-26 even in sparsely distributed Alzheimer's ß-amyloid plaques and that it enables enhanced imaging of multiply acetylated histone H4 isoforms in response to pharmacological histone deacetylase inhibition in vivo. We conclude that RP-PCA denoising may be a useful preprocessing step in biomarker discovery workflows.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Processamento de Imagem Assistida por Computador / Análise de Componente Principal / Doença de Alzheimer Tipo de estudo: Prognostic_studies Limite: Animals / Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Processamento de Imagem Assistida por Computador / Análise de Componente Principal / Doença de Alzheimer Tipo de estudo: Prognostic_studies Limite: Animals / Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article