Your browser doesn't support javascript.
loading
Early complications following cemented modular hip hemiarthroplasty.
Sullivan, Niall P T; Hughes, Andrew W; Halliday, Ruth L; Ward, Abigail L; Chesser, Tim J S.
Afiliação
  • Sullivan NP; Department of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
  • Hughes AW; Department of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
  • Halliday RL; Department of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
  • Ward AL; Department of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
  • Chesser TJ; Department of Trauma and Orthopaedics, Southmead Hospital, North Bristol NHS Trust, Southmead Way, Bristol, BS10 5NB, UK.
Open Orthop J ; 9: 15-9, 2015.
Article em En | MEDLINE | ID: mdl-25685248
ABSTRACT

INTRODUCTION:

Hemiarthroplasty is the recommended treatment for displaced, intracapsular, femoral neck fractures. This study aimed to evaluate the early complications following insertion of the JRI Furlong cemented hemiarthroplasty, a contemporary, modular, double tapered, polished prosthesis.

METHOD:

A series of 459 consecutive patients (May 2006 - June 2009) treated with a JRI hemiarthroplasty with a minimum of one-year (1-4years) follow-up were evaluated. Data collected retrospectively from clinical records and hospital databases included patient demographics, mortality, deep infection, dislocation, periprosthetic fracture, and any requirement for revision or complications related to the prosthesis.

RESULTS:

Full data were available for 429 of 459 (93%), partial data for 30 (7%). Average age was 83 years (52-100), 76% were female. One-year mortality was 24%. Intraoperative fractures occurred in 17 patients (3.7%). There were two intraoperative deaths. There were nine early deep wound infections (2%). There were two revisions to total hip replacement (THR), four patients required conversion to THR and one underwent an excision arthroplasty procedure.

DISCUSSION:

Early surgical outcomes for the JRI hemiarthroplasty prosthesis are equivalent or superior to other major hemiarthroplasty prostheses previously reported however, there was a high intraoperative fracture rate of 3.7%. We recommend using a stem one size smaller than the final broach in fragile, osteoporotic bone. No patients re-presented with aseptic loosening or stem failure.