Your browser doesn't support javascript.
loading
Sol-gel deposition of iridium oxide for biomedical micro-devices.
Nguyen, Cuong M; Rao, Smitha; Yang, Xuesong; Dubey, Souvik; Mays, Jeffrey; Cao, Hung; Chiao, Jung-Chih.
Afiliação
  • Nguyen CM; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. cmnguyen@mavs.uta.edu.
  • Rao S; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. smitha@uta.edu.
  • Yang X; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. xuesong.yang@mavs.uta.edu.
  • Dubey S; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. souvik.dubey@mavs.uta.edu.
  • Mays J; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. jeffrey.mays@mavs.uta.edu.
  • Cao H; Department of Electrical Engineering, ETS, Montreal, QC H3C 1K3, Canada. Hung.Cao@lacime.etsmtl.ca.
  • Chiao JC; Department of Electrical Engineering, University of Texas, Arlington, TX 76019, USA. jcchiao@uta.edu.
Sensors (Basel) ; 15(2): 4212-28, 2015 Feb 12.
Article em En | MEDLINE | ID: mdl-25686309
ABSTRACT
Flexible iridium oxide (IrOx)-based micro-electrodes were fabricated on flexible polyimide substrates using a sol-gel deposition process for utilization as integrated pseudo-reference electrodes for bio-electrochemical sensing applications. The fabrication method yields reliable miniature on-probe IrOx electrodes with long lifetime, high stability and repeatability. Such sensors can be used for long-term measurements. Various dimensions of sol-gel iridium oxide electrodes including 1 mm × 1 mm, 500 µm × 500 µm, and 100 µm × 100 µm were fabricated. Sensor longevity and pH dependence were investigated by immersing the electrodes in hydrochloric acid, fetal bovine serum (FBS), and sodium hydroxide solutions for 30 days. Less pH dependent responses, compared to IrOx electrodes fabricated by electrochemical deposition processes, were measured at 58.8 ± 0.4 mV/pH, 53.8 ± 1.3 mV/pH and 48 ± 0.6 mV/pH, respectively. The on-probe IrOx pseudo-reference electrodes were utilized for dopamine sensing. The baseline responses of the sensors were higher than the one using an external Ag/AgCl reference electrode. Using IrOx reference electrodes integrated on the same probe with working electrodes eliminated the use of cytotoxic Ag/AgCl reference electrode without loss in sensitivity. This enables employing such sensors in long-term recording of concentrations of neurotransmitters in central nervous systems of animals and humans.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Neurotransmissores / Irídio / Microeletrodos Limite: Animals / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Neurotransmissores / Irídio / Microeletrodos Limite: Animals / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article