Your browser doesn't support javascript.
loading
Risk Factors for Subsidence of a Modular Tapered Femoral Stem Used for Revision Total Hip Arthroplasty.
Tangsataporn, Suksan; Safir, Oleg A; Vincent, Alexander D; Abdelbary, Hesham; Gross, Allan E; Kuzyk, Paul R T.
Afiliação
  • Tangsataporn S; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
  • Safir OA; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
  • Vincent AD; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
  • Abdelbary H; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
  • Gross AE; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
  • Kuzyk PR; Mount Sinai Hospital, Toronto, Ontario, Canada; University of Toronto, Division of Orthopaedic Surgery, Department of Surgery, Toronto, Ontario, Canada.
J Arthroplasty ; 30(6): 1030-4, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25701193
ABSTRACT
The purpose of this study was to determine the incidence, and the clinical and radiographic risk factors for significant subsidence of a cementless, modular tapered revision femoral stem. Femoral stem subsidence of at least 10 mm or subsidence requiring revision was considered significant subsidence. Ninety-seven patients (99 hips) were included with minimum radiographic follow-up of one year (mean 34 months; range, 12-91 months). The mean stem subsidence was 4.5 mm (range, 0-44 mm). Fourteen out of 99 (14.1%) stems had significant subsidence and 6 (6.1%) stems required revision due to subsidence. Patient weight greater than 80 kg (P=0.04) and femoral stem press-fit distance of less than 2 cm (P<0.01) were both independent risk factors for significant stem subsidence.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Artroplastia de Quadril / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reoperação / Artroplastia de Quadril / Fêmur / Prótese de Quadril Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article