Your browser doesn't support javascript.
loading
A rapid and sensitive UPLC-MS/MS method for the simultaneous quantification of serum androsterone glucuronide, etiocholanolone glucuronide, and androstan-3α, 17ß diol 17-glucuronide in postmenopausal women.
Ke, Yuyong; Gonthier, Renaud; Isabelle, Maxim; Bertin, Jonathan; Simard, Jean-Nicolas; Dury, Alain Y; Labrie, Fernand.
Afiliação
  • Ke Y; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Gonthier R; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Isabelle M; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Bertin J; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Simard JN; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Dury AY; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada.
  • Labrie F; EndoCeutics Inc., Quebec City, QC G1V 4M7, Canada. Electronic address: fernand.labrie@endoceutics.com.
J Steroid Biochem Mol Biol ; 149: 146-52, 2015 May.
Article em En | MEDLINE | ID: mdl-25701608
ABSTRACT
Quantification of steroidal glucuronide conjugates by the indirect methods of immunoassay and GC-MS/MS may underestimate some conjugates since hydrolysis is needed in sample processing. In the present work, a sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous direct quantification of androsterone glucuronide, etiocholanolone glucuronide, and androstan-3α, 17ß diol 17-glucuronide in postmenopausal women's serum. The quantification limits are 0.1ng/mL for 3α-diol-17G and 4ng/mL for both ADT-G and Etio-G, respectively, with an extraction from 200µL serum while the total run time is less than 6min for all three glucuronides. In this method, solid phase extraction is used for sample preparation. The assay has been validated in compliance with EndoCeutics SOPs and FDA guidelines for bioanalytical method development and validation. The recovery of glucuronides in stripped serum is consistent with that in unstripped serum, where the average difference in stripped and unstripped is less than 10%. A linear regression model fits well the standard curves of all three compounds with R≥0.99 where the weighting factor is 1/X. Interday accuracy and CV for all levels of QCs are within the range of 15% in both stripped and unstripped serum while all calibration curves are within the range of 6% except for LLOQs, which are within the range of 9%. Other parameters have also been assessed such as selectivity, matrix, lipemic and hemolysis effects as well as stabilities in solution and matrix. Incurred sample reanalysis has been performed with a result of over 93% within 20% of the original values. This reliable, sensitive and fast method is ready for large-scale clinical sample assays.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Pós-Menopausa / Espectrometria de Massas em Tandem / Androstano-3,17-diol / Androsterona Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Pós-Menopausa / Espectrometria de Massas em Tandem / Androstano-3,17-diol / Androsterona Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Limite: Female / Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article