Your browser doesn't support javascript.
loading
Characteristics of idiopathic ventricular tachycardia originating above the pulmonary valve.
Yokoshiki, Hisashi; Mizukami, Kazuya; Mitsuyama, Hirofumi; Watanabe, Masaya; Tenma, Taro; Tsutsui, Hiroyuki.
Afiliação
  • Yokoshiki H; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan. yokoshh@med.hokudai.ac.jp.
  • Mizukami K; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
  • Mitsuyama H; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
  • Watanabe M; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
  • Tenma T; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
  • Tsutsui H; Department of Cardiovascular Medicine, Hokkaido University Graduate School of Medicine, Kita-15, Nishi-7, Kita-ku, Sapporo, 060-8638, Japan.
Heart Vessels ; 31(4): 599-607, 2016 Apr.
Article em En | MEDLINE | ID: mdl-25733016
ABSTRACT
Panoptic studies of ventricular tachycardia (VT) originating above the pulmonary valve are scarce. The purpose of this study is to clarify the characteristic of idiopathic VT arising above pulmonary valve. We analyzed 15 consecutive patients with idiopathic VT that was successfully abolished by catheter ablation at the right ventricular outflow tract (RVOT-VT, n = 11) and above the pulmonary valve (PA-VT, n = 4). Incidence of syncope was higher in PA-VT than RVOT-VT (100 vs 27 %, P < 0.05) and polymorphic VT was also more prevalent in PA-VT (75 vs 0 %, P < 0.05). The coupling interval (315 ± 29 vs 449 ± 32 ms, mean ± SE) at the onset of VT and minimum cycle length (CL) (192 ± 13 vs 344 ± 37 ms) during VT were shorter in PA-VT (both P < 0.05). Among 12-lead ECG parameters, only R-wave amplitude in lead II was different between groups (2.05 ± 0.17 mV in PA-VT vs 1.44 ± 0.05 mV in RVOT-VT, P < 0.005). At the successful ablation site, the activation time from the onset of QRS complex did not differ between groups (-37 ± 3 vs -31 ± 4, P = 0.405), whereas, the amplitude of intracardiac electrograms was significantly lower in PA-VT (0.83 ± 0.38 mV vs 2.39 ± 0.36 mV, P < 0.05). Although the number of patients in this study is limited, VT originating above the pulmonary valve demonstrated rapid excitation and often degenerated into polymorphic VT, suggesting its malignant electrophysiological characteristics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Bloqueio de Ramo / Taquicardia Ventricular / Ablação por Cateter / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Pulmonar / Bloqueio de Ramo / Taquicardia Ventricular / Ablação por Cateter / Ventrículos do Coração Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article