Your browser doesn't support javascript.
loading
A highly sensitive fluorescence probe for metallothioneins based on tiron-copper complex.
Xiao, Xilin; Xue, Jinhua; Liao, Lifu; Huang, Mingyang; Zhou, Bin; He, Bo.
Afiliação
  • Xiao X; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China. Electronic address: xiaoxl2001@163.com.
  • Xue J; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China.
  • Liao L; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China.
  • Huang M; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China.
  • Zhou B; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China.
  • He B; College of Chemistry and Chemical Engineering, College of Public Health, Institute of Pathogenic Biology, University of South China, Hengyang City, 421001 Hunan Province, PR China.
Article em En | MEDLINE | ID: mdl-25767991
ABSTRACT
The fabrication of tiron-copper complex as a novel fluorescence probe for the sensitive directly detection of metallothioneins at nanomolar levels was demonstrated. In Britton-Robinson (B-R) buffer (pH 7.50), the interaction of bis(tiron)copper(II) complex cation [Cu(tiron)2](2+) and metallothioneins enhanced the fluorescence intensity of the system. The fluorescence enhancement at 347 nm was proportional to the concentration of metallothioneins. The mechanism was studied and discussed in terms of the fluorescence spectra. Under the optimal experimental conditions, at 347 nm, there was a linear relationship between the fluorescence intensity and the concentration of the metallothioneins in the range of 8.80 × 10(-9)-7.70 × 10(-7)mol L(-1), with a correlation coefficient of r=0.995 and detection limit 2.60 × 10(-9)mol L(-1). The relative standard deviation was 0.77% (n=11), and the average recovery 94.4%. The method proposed was successfully reliable, selective and sensitive in determining of trace metallothioneins in fish visceral organ samples with the results in good agreement with those obtained by HPLC.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sal Dissódico do Ácido 1,2-Di-Hidroxibenzeno-3,5 Dissulfônico / Cobre / Corantes Fluorescentes / Metalotioneína Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sal Dissódico do Ácido 1,2-Di-Hidroxibenzeno-3,5 Dissulfônico / Cobre / Corantes Fluorescentes / Metalotioneína Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article