Your browser doesn't support javascript.
loading
Inflammatory cytokine release is affected by surface morphology and chemistry of titanium implants.
Östberg, Anna-Karin; Dahlgren, Ulf; Sul, Young-Taeg; Johansson, Carina B.
Afiliação
  • Östberg AK; Department of Oral Microbiology and Immunology, The Sahlgrenska Academy, Institute of Odontology, University of Gothenburg, P.O. Box 450, 405 30, Göteborg, Sweden.
J Mater Sci Mater Med ; 26(4): 155, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25779512
To investigate in vitro cellular cytokine expression in relation to commercially pure titanium discs, comparing a native surface to a fluorinated oxide nanotube surface. Control samples pure titanium discs with a homogenous wave of the margins and grooves and an often smeared-out surface structure. Test samples pure titanium discs with a fluorinated titanium oxide chemistry and surface morphology with nanopore/tube geometry characterized by ordered structures of nanotubes with a diameter of ≈ 120 nm, a spacing of ≈ 30 nm, and a wall thickness of ≈ 10 nm. Cross-section view showed vertically aligned nanotubes with similar lengths of ≈ 700 nm. Peripheral blood mononuclear leucocytes were cultured for 1, 3, and 6 days according to standard procedures. BioPlex Pro™ assays were used for analysis and detection of cytokines. Selected inflammatory cytokines are reported. A pronounced difference in production of the inflammatogenic cytokines was observed. Leucocytes exposed to control coins produced significantly more TNF-α, IL-1ß, and IL-6 than the test nanotube coins. The effect on the TH2 cytokine IL-4 was less pronounced at day 6 compared to days 1 and 3, and slightly higher expressed on the control coins. The morphology and surface chemistry of the titanium surface have a profound impact on basic cytokine production in vitro. Within the limitations of the present study, it seems that the fluorinated oxide nanotube surface results in a lower inflammatory response compared to a rather flat surface that seems to favour inflammation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Titânio / Leucócitos Mononucleares / Citocinas / Nanotubos / Inflamação Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Titânio / Leucócitos Mononucleares / Citocinas / Nanotubos / Inflamação Tipo de estudo: Etiology_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article