Your browser doesn't support javascript.
loading
Initial clinical experience with the micromesh Roadsaver carotid artery stent for the treatment of patients with symptomatic carotid artery disease.
Hopf-Jensen, Silke; Marques, Leonardo; Preiß, Michael; Müller-Hülsbeck, Stefan.
Afiliação
  • Hopf-Jensen S; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Germany hopfsi@diako.de.
  • Marques L; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Germany.
  • Preiß M; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Germany.
  • Müller-Hülsbeck S; Department of Diagnostic and Interventional Radiology and Neuroradiology, Diakonissenhospital Flensburg, Germany.
J Endovasc Ther ; 22(2): 220-5, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25809366
ABSTRACT

PURPOSE:

To assess the effectiveness, technical aspects, handling, and safety of the micromesh Roadsaver Carotid Artery Stent in the treatment of atherosclerotic carotid artery stenosis and tandem lesions in ischemic stroke patients.

METHODS:

Seven patients (5 men; mean age 75±11.4 years, range 53-86) suffering from symptomatic internal carotid artery (ICA) stenosis (mean 76% diameter reduction) were treated with the dual layer closed-cell stent without embolic protection. Postdilation was performed in 6 of 7 patients. Two patients were treated in the context of ischemic stroke and concurrent middle cerebral artery occlusion. Mean National Institutes of Health Stroke Scale score at admission was 12.8±5.

RESULTS:

All devices were deployed satisfactorily. One wall-adherent thromboembolus in a proximal ICA was covered with the Roadsaver stent in a tandem lesion setting. The modified Rankin Scale (mRS) declined from 3.7±0.7 to 2.4±0.8 in hospital, showing an improvement in clinical symptoms. No complications were detected during or after the procedure. The 30-day mRS was 1.7±1.1. At 6 months, ultrasound examination demonstrated patency of stents and the external carotid arteries.

CONCLUSION:

The Roadsaver double layer micromesh stent seems to be safe and effective in the treatment of extracranial ICA stenosis and in the context of tandem lesions in ischemic stroke. Further studies with larger populations are warranted.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Carótida Interna / Stents / Estenose das Carótidas / Angioplastia com Balão Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artéria Carótida Interna / Stents / Estenose das Carótidas / Angioplastia com Balão Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article