Clinical evaluation of the v-gel supraglottic airway device in comparison with a classical laryngeal mask and endotracheal intubation in cats during spontaneous and controlled mechanical ventilation.
Prasse, Sarah A; Schrack, Johanna; Wenger, Sandra; Mosing, Martina.
Afiliação
  • Prasse SA; Section of Anaesthesiology, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
  • Schrack J; Section of Small Animal Reproduction, Clinic of Reproductive Medicine, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
  • Wenger S; Clinic for Zoo Animals, Exotic Pets and Wildlife, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
  • Mosing M; Section of Anaesthesiology, Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Vet Anaesth Analg ; 43(1): 55-62, 2016 Jan.
Article em En | MEDLINE | ID: mdl-25819338
ABSTRACT

OBJECTIVE:

To compare airway management during induction of anaesthesia, in spontaneous ventilation and controlled mechanical ventilation (CMV), using a cat-specific supraglottic airway device (the v-gel), a classical laryngeal mask (LM) or an endotracheal tube (ETT). STUDY

DESIGN:

Prospective, randomized clinical trial. ANIMALS Forty-five healthy cats.

METHODS:

After premedication, cats were randomly allocated to one of three groups to secure the airway 1) v-gel; 2) LM; or 3) ETT (cuff pressure 20 cm H2O). Cats were anaesthetized for elective procedures. The dose of propofol necessary to insert the v-gel, LM or ETT, the number of attempts required to achieve insertion and leakage during spontaneous ventilation and CMV at different peak inspiratory pressures (8, 10, 12, 14 and 16 cm H2O) were recorded. Leakage of >20% of tidal volume was considered as a criterion for exclusion. Significance was set at a p-value of <0.05.

RESULTS:

Cats in the v-gel group required a median (range) of 3 mg kg(-1) (2-5 mg kg(-1)) of propofol for successful placement, which was significantly less than the 5 mg kg(-1) (3-7 mg kg(-1)) required for endotracheal intubation (p = 0.005). No significant difference in the total dose of propofol was observed between the v-gel and LM [3 mg kg(-1) (2-7 mg kg(-1))] groups or the ETT and LM groups. Significantly more cats in the ETT group were excluded for leakage of >20% during CMV at all pressure settings. CONCLUSIONS AND CLINICAL RELEVANCE The v-gel is a practical alternative to the LM and ETT for securing the airway after induction of anaesthesia and for CMV up to 16 cm H2O in healthy cats. The v-gel can be inserted at a more superficial level of anaesthesia than the ETT and showed significantly less leakage during CMV than the ETT.