Your browser doesn't support javascript.
loading
The self-adjusting file instrumentation results in less debris extrusion apically when compared to WaveOne and ProTaper NEXT.
Pawar, Ajinkya M; Pawar, Mansing G; Metzger, Zvi; Kokate, Sharad R.
Afiliação
  • Pawar AM; Department of Conservative Dentistry and Endodontics, Dnyandeo Yashwantrao Patil Dental School and Hospital, Lohegaon, Pune, India.
  • Pawar MG; Department of Conservative Dentistry and Endodontics, Government Dental College and Hospital, Mumbai, India.
  • Metzger Z; Department of Endodontology, The Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Kokate SR; Department of Conservative Dentistry and Endodontics, Yashwant Memorial Trust Dental College and Hospital, Kharghar, Navi-Mumbai, Maharashtra, India.
J Conserv Dent ; 18(2): 89-93, 2015.
Article em En | MEDLINE | ID: mdl-25829683
AIM: The present ex vivo study aimed to evaluate the debris extrusion after instrumenting the root canals by three different files systems. MATERIALS AND METHODS: Sixty extracted human mandibular premolars with single canals were selected and randomly divided into three groups (n = 20) for instrumentation with three different files. Group 1: WaveOne (primary) single reciprocating file (WO; Dentsply Maillefer, Ballaigues, Switzerland) (25/08), Group 2: Self-adjusting file (SAF; ReDent-Nova, Ra'anana, Israel) (1.5 mm), and Group 3: ProTaper NEXT X1 and X2 (PTN; Dentsply Tulsa Dental, Tulsa, OK) (25/06). Debris extruding by instrumentation were collected into pre-weighed Eppendorf tubes. These tubes were then stored in an incubator at 70°C for 5 days. The tubes were then weighed to obtain the final weight, with the extruded debris. Statistical analysis for the debris extruded apically was performed using one-way analysis of variance and post hoc Tukey's test. RESULTS: The statistical analysis showed a significant difference between all the three groups tested (P < 0.01). The following post hoc Tukey's test confirmed that Group 2 (SAF) exhibited significantly least (P < 0.01) debris extrusion between the three groups tested. CONCLUSIONS: The SAF resulted in significantly less extrusion of debris when compared to reciprocating WO and rotary PTN.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2015 Tipo de documento: Article