Your browser doesn't support javascript.
loading
Rapid in vivo multicomponent T2 mapping of human knee menisci.
Liu, Fang; Samsonov, Alexey; Wilson, John J; Blankenbaker, Donna G; Block, Walter F; Kijowski, Richard.
Afiliação
  • Liu F; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Samsonov A; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Wilson JJ; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Blankenbaker DG; Department of Orthopedics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Block WF; Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
  • Kijowski R; Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin, USA.
J Magn Reson Imaging ; 42(5): 1321-8, 2015 Nov.
Article em En | MEDLINE | ID: mdl-25847733
ABSTRACT

PURPOSE:

To compare multicomponent T2 parameters of menisci measured using Multicomponent Driven Equilibrium Single Pulse Observation of T1 and T2 (mcDESPOT) in asymptomatic volunteers and osteoarthritis (OA) patients with intact and torn menisci. MATERIALS AND

METHODS:

The prospective study was performed with Institutional Review Board approval and with all subjects signing written informed consent. mcDESPOT was performed on the knee joint of 12 asymptomatic volunteers and 14 patients with knee OA. Single-component T2 relaxation time (T2Single ), T2 relaxation time of the fast relaxing water component (T2F ), and the slow relaxing water component (T2S ), and fraction of the fast relaxing water component (FF ) of the medial and lateral menisci were measured. Multivariate linear regression models were used to compare mcDESPOT parameters between normal menisci in asymptomatic volunteers, intact menisci in OA patients, and torn menisci in OA patients with adjustment for differences in age between subjects.

RESULTS:

The mean mcDESPOT parameters for normal menisci in asymptomatic volunteers, intact menisci in OA patients, and torn menisci in OA patients were respectively 16.1 msec, 18.8 msec, and 22.7 msec for T2Single ; 9.0 msec, 10.0 msec, and 11.1 msec for T2F ; 24.4 msec, 27.7 msec, and 31.4 msec for T2S ; and 34%, 32%, 27% for FF . There were significant differences (P < 0.05) in T2Single , T2F , T2S , and FF between the three groups of menisci.

CONCLUSION:

The menisci of OA patients had significantly higher T2Single , T2F , and T2S and significantly lower FF than normal menisci in asymptomatic volunteers with greater changes in multicomponent T2 parameters noted in torn than intact menisci in OA patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Meniscos Tibiais / Imageamento por Ressonância Magnética / Cartilagem Articular / Osteoartrite do Joelho / Traumatismos do Joelho Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Meniscos Tibiais / Imageamento por Ressonância Magnética / Cartilagem Articular / Osteoartrite do Joelho / Traumatismos do Joelho Tipo de estudo: Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article