iStent inject in phakic open angle glaucoma.
Klamann, Matthias K J; Gonnermann, Johannes; Pahlitzsch, Milena; Maier, Anna-Karina B; Joussen, Antonia M; Torun, Necip; Bertelmann, Eckart.
Afiliação
  • Klamann MK; Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Augustenburger Platz 1, 13353, Berlin, Germany, matthias@klamann.net.
Graefes Arch Clin Exp Ophthalmol ; 253(6): 941-7, 2015 Jun.
Article em En | MEDLINE | ID: mdl-25912085
ABSTRACT

BACKGROUND:

The effectiveness and complication profile of the iStent inject implantation among different open angle glaucoma subgroups were analyzed.

METHODS:

In this retrospective cohort outcome study, 35 consecutive patients suffering from glaucoma (primary open angle glaucoma (POAG) N = 17, pseudoexfoliation glaucoma (PEX) N = 15, and pigmentary glaucoma (PG) N = 3) were treated with the iStent inject. The intraocular pressure (IOP) and the number of antiglaucoma medications before and after surgery were evaluated.

RESULTS:

In POAG, the mean IOP at 6 months measured 14.19 ± 1.38 mmHg with an average decrease of 33 % from preoperative IOP (p < 0.001), and 15.33 ± 1.07 mmHg with an average decrease of 35 % in PEX (p < 0.001), respectively. The number of antiglaucoma medications significantly decreased from 2.19 ± 0.91 to 0.88 ± 0.62 in POAG (p < 0.001) and from 2.33 ± 1.23 to 1.04 ± 0.30 in PEX (p < 0.001) after 6 months. In PG, IOP before surgery was 28.31 ± 3.21 mmHg and the number of antiglaucoma medications was 3.66 ± 0.57. One day after surgery, IOP decreased significantly to 12.33 mmHg ± 4.93 (p < 0.001). Within four weeks after surgery, IOP was raised above 30 mmHg in every patient. To exclude a steroid response, topical steroids were stopped, but IOP did not decrease. To exclude blockage, NdYAG - laser treatment of the visible opening of the iStents was performed. Since the IOP stayed high and escalation of antiglaucoma medication was insufficient to control IOP, trabeculectomy was performed.

CONCLUSIONS:

In conclusion, implantation of the iStent inject has the ability to lower the postoperative IOP significantly in POAG and PEX after a short follow-up of 6 months with a favorable risk profile. However, limitation of this surgical procedure in phakic PG may exist and need to be investigated in further studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malha Trabecular / Glaucoma de Ângulo Aberto / Implantes para Drenagem de Glaucoma / Cristalino Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Malha Trabecular / Glaucoma de Ângulo Aberto / Implantes para Drenagem de Glaucoma / Cristalino Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article