Bacterial contamination of suction catheter tips during aortic valve replacement surgery: a prospective observational cohort study.
Larsson, Johanna; Sutherland, Sofia; Söderström, Åsa; Roman-Emanuel, Christine; Jeppsson, Anders; Olofsson, Elisabeth Hansson; Svensson, Per-Arne.
Afiliação
  • Larsson J; Institute of Health and Care Sciences, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Sutherland S; Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Söderström Å; Institute of Health and Care Sciences, The Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
  • Roman-Emanuel C; Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Jeppsson A; Department of Anaesthesia and Intensive Care, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Olofsson EH; Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
  • Svensson PA; Department of Cardiothoracic Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden.
Patient Saf Surg ; 9: 17, 2015.
Article em En | MEDLINE | ID: mdl-25972923
ABSTRACT

BACKGROUND:

Bacterial mediastinitis is a severe complication after open heart surgery. The infection causes prolonged hospitalization and an increased mortality risk. Observations from orthopaedic surgery showed that the suction catheter used during surgery is commonly contaminated with bacteria. The aim of this study was to describe the prevalence of suction catheter contamination in cardiac surgery and to study if suction time influences the contamination risk.

METHODS:

Fifty suction catheter tips were collected during 25 aortic valve replacement operations. The suction tip was exchanged once during the operation (after aortotomy closure). The tips were subjected to bacterial contamination analysis.

RESULTS:

In 20 of the 25 investigated cases (80%), bacterial contamination was detected on one or both tips. The tip used during the beginning of the operation showed bacterial contamination in 13/25 cases (52%) and the second tip in 12/25 (48%). In 5/25 cases (20%) both tips were contaminated. There was no association between bacterial contamination and suction time. Coagulase-negative staphylococcus was the most commonly detected microorganism.

CONCLUSIONS:

The suction device should be considered as a potential source of bacterial contamination in cardiac surgery. The results suggest that the suction catheter should be replaced before key moments like valve implantation and sternal closure.