Determination and validation of hupehenine in rat plasma by UPLC-MS/MS and its application to pharmacokinetic study.
Wen, Congcong; Wang, Shuanghu; Huang, Xueli; Liu, Zezheng; Lin, Yingying; Yang, Suping; Ma, Jianshe; Zhou, Yunfang; Wang, Xianqin.
Afiliação
  • Wen C; Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, 325035, China.
  • Wang S; The Laboratory of Clinical Pharmacy, The People's Hospital of Lishui 323000, Wenzhou Medical University, Lishui, China.
  • Huang X; Analytical and Testing Center, Wenzhou Medical University, Wenzhou, 325035, China.
  • Liu Z; Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, 325035, China.
  • Lin Y; Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, 325035, China.
  • Yang S; Laboratory Animal Centre, Wenzhou Medical University, Wenzhou, 325035, China.
  • Ma J; Analytical and Testing Center, Wenzhou Medical University, Wenzhou, 325035, China.
  • Zhou Y; The Laboratory of Clinical Pharmacy, The People's Hospital of Lishui 323000, Wenzhou Medical University, Lishui, China.
  • Wang X; Analytical and Testing Center, Wenzhou Medical University, Wenzhou, 325035, China.
Biomed Chromatogr ; 29(12): 1805-10, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26033449
ABSTRACT
In this work, a sensitive and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determination of hupehenine in rat plasma was developed and validated. After addition of imperialine as an internal standard (IS), protein precipitation by acetonitrile-methanol (91, v/v) was used to prepare samples. Chromatographic separation was achieved on a UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with 0.1% formic acid and acetonitrile as the mobile phase with gradient elution. An electrospray ionization source was applied and operated in positive ion mode; multiple reaction monitoring mode was used for quantification using target fragment ions m/z 416.3 → 98.0 for hupehenine, and m/z 430.3 → 138.2 for IS. Calibration plots were linear throughout the range 2-2000 ng/mL for hupehenine in rat plasma. Mean recoveries of hupehenine in rat plasma ranged from 92.5 to 97.3%. Relative standard deviations of intra-day and inter-day precision were both <6%. The accuracy of the method was between 92.7 and 107.4%. The method was successfully applied to a pharmacokinetic study of hupehenine after either oral or intravenous administration. For the first time, the bioavailability of hupehenine was reported as 13.4%.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Alcaloides / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cromatografia Líquida de Alta Pressão / Alcaloides / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article