Your browser doesn't support javascript.
loading
Can Sequentially-irradiated and Annealed Highly Cross-linked Polyethylene Inserts Thinner than Eight-millimeters Be Utilized in Total Knee Arthroplasty?
Sayeed, Siraj A; Jauregui, Julio J; Korduba, Laryssa A; Essner, Aaron; Harwin, Steven F; Delanois, Ronald E; Mont, Michael A.
Afiliação
  • Sayeed SA; Department of Orthopaedic Surgery, South Texas Bone and Joint Institute, San Antonio, Texas.
  • Jauregui JJ; Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland.
  • Korduba LA; Orthopaedic Department, Stryker Orthopaedics, Mahwah, New Jersey.
  • Essner A; Orthopaedic Department, Stryker Orthopaedics, Mahwah, New Jersey.
  • Harwin SF; Department of Orthopaedic Surgery, Beth Israel Medical Center, New York, New York.
  • Delanois RE; Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland.
  • Mont MA; Department of Orthopaedic Surgery, Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Baltimore, Maryland.
Surg Technol Int ; 26: 329-35, 2015 May.
Article em En | MEDLINE | ID: mdl-26055028
ABSTRACT
The routine use of highly cross-linked ultra-high molecular weight polyethylene (UHMWPE) has remained controversial secondary to the possibility of decreased material properties when compared to conventional UHMWPE. The aim of the present study was to evaluate if thin, sequentially-irradiated, and annealed highly cross-linked UHMWPE tibial inserts would have improved wear properties, while maintaining mechanical integrity, compared to conventional UHMWPE during biomechanical testing under aligned and malaligned conditions. Polyethylene inserts (4.27 and 6.27 mm) manufactured from GUR 1020-UHMWPE were cyclically loaded to analyze for wear. All wear scars were visually examined after loading using scanning electron microscopy (SEM). Volume loss was plotted versus cycle count with linear regression analysis yielding wear rates. There was no statistical difference in wear between both thicknesses for all testing conditions. During aligned condition testing, the volumetric wear rate for sequentially-irradiated and annealed polyethylene thicknesses of 4.27 and 6.27 mm was 4.0 and 4.4 mm3/million cycles; and during malaligned conditions, it was 13.9 and 15.1 mm3/million cycles. For conventional polyethylene during aligned conditions, the volumetric wear rate was 33.0 and 22.8 mm3/million cycles; and during malaligned conditions it was 50.0 and 50.8 mm3/million cycles. By SEM evaluation, condylar wear surfaces for conventional and sequentially-irradiated and annealed polyethylene displayed surface ripples typical of adhesive wear. There were no observed visible differences between the wear scars for conventional compared to sequentially-irradiated and annealed polyethylene with no evidence of fatigue failure. This study demonstrated no differences between polyethylenes with thicknesses of 4.27 and 6.27 mm. This strengthens the conclusion that sequentially-irradiated and annealed highly cross-linked UHMWPE can be utilized in total knee arthroplasty. The successful wear properties of 4.27 mm liners could mean that smaller tibial resections leading to bone stock preservation could be utilized in patients undergoing total knee arthroplasty, although further in-vivo studies are needed.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenos / Desenho de Prótese / Teste de Materiais / Artroplastia do Joelho / Prótese do Joelho Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polietilenos / Desenho de Prótese / Teste de Materiais / Artroplastia do Joelho / Prótese do Joelho Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article