Your browser doesn't support javascript.
loading
Performance of rapid tests for discrimination between HIV-1 and/or HIV-2 infections.
Gautheret-Dejean, Agnès; Bocobza, Jonathan; Brunet, Sylvie; Damond, Florence; Plantier, Jean-Christophe; Barin, Francis.
Afiliação
  • Gautheret-Dejean A; Sorbonne Universités, UPMC Université Paris 6, UMRS CR7, INSERM U1135, Persistent Viral Infections, CIMI-Paris, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Paris, France.
  • Bocobza J; AP-HP, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Service de Virologie, Paris, France.
  • Brunet S; Sorbonne Paris Cité, Université René Descartes Paris 5, UFR des Sciences Pharmaceutiques et Biologiques, Laboratoire de Microbiologie, Paris, France.
  • Damond F; Sorbonne Universités, UPMC Université Paris 6, UMRS CR7, INSERM U1135, Persistent Viral Infections, CIMI-Paris, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Paris, France.
  • Plantier JC; AP-HP, Hôpitaux Universitaires La Pitié Salpêtrière-Charles Foix, Service de Virologie, Paris, France.
  • Barin F; Centre Hospitalier Régional Universitaire, Centre National de Référence du VIH, Tours, France.
J Med Virol ; 87(12): 2061-6, 2015 Dec.
Article em En | MEDLINE | ID: mdl-26081750
Major differences exist between HIV-1 and HIV-2 in terms of epidemiology, pathogenicity, sensitivity to antiretrovirals. Determining the type of HIV infecting a patient is essential for management. The aim of this study was to evaluate the ability of simple/rapid tests to differentiate between HIV-1 and/or HIV-2 infections. We analyzed 116 samples from patients infected with HIV-1 (n = 61), HIV-2 (n = 47), or HIV-1+HIV-2 (n = 8) at the chronic stage of infection. Each sample was tested with SD Bioline HIV-1/2 3.0, ImmunoFlow HIV1-HIV2, ImmunoFlow HIV1-HIV2 (WB), Genie III HIV-1/HIV-2, ImmunoComb HIV1&2 BiSpot. HIV-1, or HIV-2 single infection was identified with a sensitivity ranging from 90% to 100%. The ability to detect dual infection was less sensitive (12.5-100%). SD Bioline HIV-1/2 3.0, ImmunoFlow HIV1-HIV2, and Genie III were unable to detect HIV-1 group O infection in one, one and two cases, respectively. The specificity of detection of HIV-1, HIV-2, or HIV-1+HIV-2 antibodies differed greatly (36-100%). ImmunoComb BiSpot had the highest sensitivity values (99-100% for HIV-1, 98% for HIV-2, and 75-87.5% for dual infection) and specificity values (94-100% for HIV-1, 100% for HIV-2, and 97-100% for dual infection). In conclusion, this study showed that no single rapid test had a perfect sensitivity/specificity ratio, particularly in the case of the double infections.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / HIV-1 / HIV-2 / Técnicas de Laboratório Clínico / Testes Diagnósticos de Rotina Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Infecções por HIV / HIV-1 / HIV-2 / Técnicas de Laboratório Clínico / Testes Diagnósticos de Rotina Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article