Your browser doesn't support javascript.
loading
Low-Dose Pelvic Computed Tomography Using Adaptive Iterative Dose Reduction 3-Dimensional Algorithm: A Phantom Study.
Onishi, Hiromitsu; Kockelkoren, Remko; Kim, Tonsok; Hori, Masatoshi; Nakamoto, Atsushi; Tsuboyama, Takahiro; Sakane, Makoto; Tatsumi, Mitsuaki; Uranishi, Ayumi; Tanaka, Toshiya; Taniguchi, Akira; Enchi, Yukihiro; Satoh, Kazuhiko; Tomiyama, Noriyuki.
Afiliação
  • Onishi H; From the *Department of Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan; †Faculty of Medical Sciences, University of Groningen, MWF-Complex, Groningen, the Netherlands, ‡Toshiba Medical Systems Corporation, Otawara-Shi, Tochigi, Japan; and §Division of Radiology, Department of Medical Technology, Osaka University Hospital, Suita, Osaka, Japan.
J Comput Assist Tomogr ; 39(4): 629-34, 2015.
Article em En | MEDLINE | ID: mdl-26125298
OBJECTIVE: To evaluate the image quality and radiation dose reduction in pelvic computed tomography (CT) achieved with an adaptive iterative dose reduction 3-dimensional (AIDR 3D) algorithm using a phantom model. METHODS: Two phantoms were scanned using a 320-detector row CT scanner with 8 tube current levels, and the images were reconstructed with a standard filtered back projection (FBP) algorithm and with an AIDR 3D algorithm. RESULTS: Compared with FBP, AIDR 3D reduced image noise and improved contrast-to-noise ratios. The diagnostic performance for detection of low-contrast targets of AIDR 3D images obtained with 100 mA at 120 kVp was almost as good as that of the FBP images obtained with 200 mA. CONCLUSIONS: The AIDR 3D algorithm substantially reduced image noise and improved the image quality of pelvic CT images compared with those obtained with the FBP algorithm and can thus be considered a promising technique for low-dose pelvic CT examinations.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Processamento de Imagem Assistida por Computador / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Imagens de Fantasmas / Imageamento Tridimensional Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Processamento de Imagem Assistida por Computador / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Imagens de Fantasmas / Imageamento Tridimensional Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article