Usefulness of non-contrast-enhanced MRI with two-dimensional balanced steady-state free precession for the acquisition of the pulmonary venous and left atrial anatomy pre catheter ablation of atrial fibrillation: Comparison with contrast enhanced CT in clinical cases.
Shigenaga, Yutaka; Okajima, Katsunori; Ikeuchi, Kazushi; Kiuchi, Kunihiko; Ikeda, Takayuki; Shimane, Akira; Yokoi, Kiminobu; Teranishi, Jin; Aoki, Kousuke; Chimura, Misato; Yamada, Shinichiro; Taniguchi, Yasuyo; Yasaka, Yoshinori; Kawai, Hiroya.
Afiliação
  • Shigenaga Y; Department of Radiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Okajima K; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Ikeuchi K; Department of Radiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Kiuchi K; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Ikeda T; Department of Radiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Shimane A; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Yokoi K; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Teranishi J; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Aoki K; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Chimura M; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Yamada S; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Taniguchi Y; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Yasaka Y; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
  • Kawai H; Department of Cardiology, Himeji Cardiovascular Center, Himeji, Hyogo, Japan.
J Magn Reson Imaging ; 43(2): 495-503, 2016 Feb.
Article em En | MEDLINE | ID: mdl-26149175
BACKGROUND: To investigate the feasibility of substituting non-contrast-enhanced MR (non-CE-MR) imaging with a two-dimensional (2D) balanced steady-state free precession (b-SSFP) sequence for contrast-enhanced computed tomography (CE-CT) for atrial fibrillation (AF) ablation. METHODS: Fifty-four patients that underwent AF ablation under the guidance of a 3D electro-anatomical mapping system with CE-CT (n = 27) or non-CE-MR images (n = 27) were studied. Procedural results were compared between the two groups. Furthermore, in 22 patients who underwent both CE-CT and non-CE-MRI, two cardiologists independently scored the multiplanar reformatted images on a scale of 1 to 4 (from 1, poor, to 4, excellent). RESULTS: The image score was nearly 0.5 point higher with the CE-CT method. However, the procedural results such as the surface registration error (1.0 [0.8-1.6] mm versus 1.0 [0.8-1.35] mm, P = 0.88) and procedure time (185 [159-199] min versus 185 [142-221] min, P = 0.86) did not significantly differ between the CE-CT and non-CE-MR groups. CONCLUSION: The non-CE-MR method with a 2D-b-SSFP sequence can give us adequate information on AF ablation without any radiation exposure or contrast medium usage
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Cuidados Pré-Operatórios / Imageamento por Ressonância Magnética / Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Meios de Contraste Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Cuidados Pré-Operatórios / Imageamento por Ressonância Magnética / Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Meios de Contraste Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article