Your browser doesn't support javascript.
loading
Can we predict the size of frequently used autografts in ACL reconstruction?
Zakko, Philip; van Eck, Carola F; Guenther, Daniel; Irrgang, James J; Fu, Freddie H.
Afiliação
  • Zakko P; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA, 15213, USA.
  • van Eck CF; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA, 15213, USA.
  • Guenther D; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA, 15213, USA.
  • Irrgang JJ; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA, 15213, USA.
  • Fu FH; Department of Orthopaedic Surgery, University of Pittsburgh, Kaufman Building Suite 1011, 3471 Fifth Avenue, Pittsburgh, PA, 15213, USA. ffu@upmc.edu.
Knee Surg Sports Traumatol Arthrosc ; 25(12): 3704-3710, 2017 Dec.
Article em En | MEDLINE | ID: mdl-26183732
PURPOSE: This study presents a method to measure the size of quadriceps, patellar tendon and hamstring autografts using preoperative magnetic resonance imaging (MRI). METHODS: Sixty-two subjects with a mean age of 25 ± 10 years who underwent ACL surgery between 2011 and 2014 were included. Patient anthropometric data were recorded for all subjects. During surgery, the respective autograft was harvested and measured using commercially available graft sizers. MRI measurements were performed by two raters, who were blinded to the intra-operative measurements. RESULTS: The inter- and intra-rater reliability was ≥0.8 for all MRI measurements. The intra-class correlation coefficient between the MRI measurement of the graft and the actual size of the harvested graft was 0.639. There were significant correlations between quadriceps tendon thickness and height (r = 0.3, p < 0.03), weight (r = 0.3, p < 0.01), BMI (r = 0.3, p < 0.04) and gender (r = -0.4, p < 0.002) and patellar tendon thickness and height (r = 0.4, p < 0.01), weight (r = 0.3, p < 0.01) and gender (r = -0.4, p < 0.012). CONCLUSION: Preoperative MRI measurements of quadriceps, patellar tendon and hamstring graft size are highly reliable with moderate-to-good accuracy. Significant correlations between patient anthropometric data and the thicknesses of the quadriceps and patellar tendons were observed. Obtaining this information can be useful for preoperative planning and to help counsel patients on appropriate graft choices prior to surgery. LEVEL OF EVIDENCE: III.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reconstrução do Ligamento Cruzado Anterior / Autoenxertos Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reconstrução do Ligamento Cruzado Anterior / Autoenxertos Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Female / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article