Safety and Hemodynamic Profile of Propofol and Dexmedetomidine Anesthesia during Intra-arterial Acute Stroke Therapy.
John, Seby; Somal, Jaspreet; Thebo, Umera; Hussain, Muhammad S; Farag, Ehab; Dupler, Suzanne; Gomes, Joao.
Afiliação
  • John S; Cerebrovascular Center, Cleveland Clinic, Cleveland, Ohio. Electronic address: johns@ccf.org.
  • Somal J; Department of General Anesthesia, Cleveland Clinic, Cleveland, Ohio.
  • Thebo U; Department of Internal Medicine, Cleveland Clinic, Cleveland, Ohio.
  • Hussain MS; Cerebrovascular Center, Cleveland Clinic, Cleveland, Ohio.
  • Farag E; Department of General Anesthesia, Cleveland Clinic, Cleveland, Ohio.
  • Dupler S; Department of General Anesthesia, Cleveland Clinic, Cleveland, Ohio.
  • Gomes J; Cerebrovascular Center, Cleveland Clinic, Cleveland, Ohio.
J Stroke Cerebrovasc Dis ; 24(10): 2397-403, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26231475
ABSTRACT

BACKGROUND:

There is limited data on the safety, hemodynamic profile, and outcome of patients undergoing intra-arterial therapy (IAT) for acute ischemic stroke (AIS) under sedation with dexmedetomidine (DEX) versus propofol (PROP).

METHODS:

Retrospective study of patients with anterior circulation AIS, who underwent IAT without intubation, and received either DEX or PROP between January 2008 and December 2012, was performed. Demographics, stroke treatments, time metrics, anesthesia, intraprocedural hemodynamics, vasopressor use, infarct volumes, recanalization status, and intracerebral hemorrhage were collected.

RESULTS:

Seventy-two patients met inclusion criteria, of which 35 received DEX and 37 PROP. There was no difference in baseline demographics, stroke treatments, successful recanalization, hemorrhages, infarct volume growth, good clinical outcome (mRS ≤ 2 [19% versus 22%, P = .742]), or in-hospital mortality (18% versus 8%, P = .225) between DEX and PROP. The DEX group had lower intraprocedural minimum systolic blood pressure (103 ± 27 versus 114 ± 18 mm Hg, P = .032) and minimum mean arterial pressure (MAP; 67 ± 17 versus 77 ± 10 mm Hg, P = .006). More patients in the DEX group experienced episodes of hypotension (MAP < 60 mm Hg; 24% versus 3%; P = .010) and had higher vasopressor requirement (phenylephrine 1825 ± 2390 versus 491 ± 884 mcg, P = .007) compared to PROP.

CONCLUSIONS:

There was no difference in good clinical outcome or in-hospital mortality in patients undergoing IAT for AIS using DEX versus PROP sedation. However, hemodynamic instability and vasopressor requirement were significantly higher in the DEX group. DEX should be cautiously utilized in IAT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propofol / Acidente Vascular Cerebral / Dexmedetomidina / Hemodinâmica / Hipnóticos e Sedativos Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Propofol / Acidente Vascular Cerebral / Dexmedetomidina / Hemodinâmica / Hipnóticos e Sedativos Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2015 Tipo de documento: Article