Your browser doesn't support javascript.
loading
Comparison of 5 types of interocclusal recording materials on the accuracy of articulation of digital models.
Sweeney, Sunya; Smith, Derek K; Messersmith, Marion.
Afiliação
  • Sweeney S; Private practice, Atlanta, Ga; assistant professor, Department of Orthodontics, Vanderbilt University Medical Center, Nashville, Tenn. Electronic address: sunya.sweeney@gmail.com.
  • Smith DK; Doctoral candidate, Department of Biostatistics, Medical Center, Vanderbilt University Nashville, Tenn.
  • Messersmith M; Associate professor, Division of Orthodontics, Medical Center, Vanderbilt University, Nashville, Tenn.
Am J Orthod Dentofacial Orthop ; 148(2): 245-52, 2015 Aug.
Article em En | MEDLINE | ID: mdl-26232833
INTRODUCTION: One method of articulating digital models is to use a digitized interocclusal record. However, the accuracy of different interocclusal record materials to articulate digital models has yet to be evaluated. METHODS: A plastic typodont was modified with reference points for interarch measurements and articulated in maximum intercuspal position on a semiadjustable hinge articulator. Twenty-five interocclusal records of each of the 5 experimental materials (Regisil Rigid, Dentsply, York, Pa; Futar Scan, Kettenbach, Huntington Beach, Calif; Byte Right, Motion View Software, Chattanooga, Tenn; Aluwax, Aluwax Dental Products, Allendale, Mich; and Beauty Pink wax, Miltex, York, Pa) were made on the mounted typodont and digitized using an Ortho Insight 3D laser surface scanner (Motion View Software). Motion View Software was used to articulate the digital models by matching points from the models to the digitized interocclusal records. The distances between corresponding interarch markers were measured and compared with the measurements taken on the physical typodont (gold standard). RESULTS: Polyvinyl siloxane materials were significantly more likely to lead to successful articulation than were the other interocclusal record materials. Statistical analysis showed a significant effect of the bite registration material on the probability of success of the articulation (P <0.005). CONCLUSIONS: Polyvinyl siloxane is a more accurate interocclusal recording material when articulating digital models according to the process described in this study. Using a bite registration to articulate digital models should be considered the first step in the articulation process, with a likely residual need to manipulate the models manually.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Materiais para Moldagem Odontológica / Modelos Dentários / Registro da Relação Maxilomandibular Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Materiais para Moldagem Odontológica / Modelos Dentários / Registro da Relação Maxilomandibular Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article