Your browser doesn't support javascript.
loading
An evaluation of the PowerSeq™ Auto System: A multiplex short tandem repeat marker kit compatible with massively parallel sequencing.
Zeng, Xiangpei; King, Jonathan; Hermanson, Spencer; Patel, Jaynish; Storts, Douglas R; Budowle, Bruce.
Afiliação
  • Zeng X; Institute of Applied Genetics, Department of Molecular and Medical Genetics, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, Texas 76107, USA. Electronic address: Xiangpei.Zeng@live.unthsc.edu.
  • King J; Institute of Applied Genetics, Department of Molecular and Medical Genetics, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, Texas 76107, USA.
  • Hermanson S; Promega Corporation, 2800 Woods Hollow Road, Madison, WI 53711, USA.
  • Patel J; Promega Corporation, 2800 Woods Hollow Road, Madison, WI 53711, USA.
  • Storts DR; Promega Corporation, 2800 Woods Hollow Road, Madison, WI 53711, USA.
  • Budowle B; Institute of Applied Genetics, Department of Molecular and Medical Genetics, University of North Texas Health Science Center, 3500 Camp Bowie Blvd., Fort Worth, Texas 76107, USA; Center of Excellence in Genomic Medicine Research (CEGMR), King Abdulaziz University, Jeddah, Saudi Arabia.
Forensic Sci Int Genet ; 19: 172-179, 2015 Nov.
Article em En | MEDLINE | ID: mdl-26240968
ABSTRACT
Capillary electrophoresis (CE) and multiplex amplification with fluorescent tagging have been routinely used for STR typing in forensic genetics. However, CE-based methods restrict the number of markers that can be multiplexed simultaneously and cannot detect any intra-repeat variations within STRs. Several studies already have indicated that massively parallel sequencing (MPS) may be another potential technology for STR typing. In this study, the prototype PowerSeq(™) Auto System (Promega) containing the 23 STR loci and amelogenin was evaluated using Illumina MiSeq. Results showed that single source complete profiles could be obtained using as little as 62 pg of input DNA. The reproducibility study showed that the profiles generated were consistent among multiple typing experiments for a given individual. The mixture study indicated that partial STR profiles of the minor contributor could be detected up to 191 mixture. The mock forensic casework study showed that full or partial profiles could be obtained from different types of single source and mixture samples. These studies indicate that the PowerSeq Auto System and the Illumina MiSeq can generate concordant results with current CE-based methods. In addition, MPS-based systems can facilitate mixture deconvolution with the detection of intra-repeat variations within length-based STR alleles.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marcadores Genéticos / Repetições de Microssatélites / Genética Forense / Sequenciamento de Nucleotídeos em Larga Escala Limite: Female / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Marcadores Genéticos / Repetições de Microssatélites / Genética Forense / Sequenciamento de Nucleotídeos em Larga Escala Limite: Female / Humans / Male Idioma: En Ano de publicação: 2015 Tipo de documento: Article