Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage--Systematic analysis of key parameters of meshes in a novel minipig hernia model.
Weyhe, Dirk; Cobb, William; Lecuivre, Julie; Alves, Antoine; Ladet, Sebastien; Lomanto, Davide; Bayon, Yves.
Afiliação
  • Weyhe D; University Hospital for Visceral Surgery, School VI - Medicine and Health Sciences, Carl von Ossietzky University Oldenburg, Oldenburg, Germany. Electronic address: dirk.weyhe@pius-hopspital.de.
  • Cobb W; The Hernia Center, Greenville Health System, Greenville, SC, USA.
  • Lecuivre J; Covidien - Sofradim Production, 116 Avenue du Formans - BP132, F-01600 Trevoux, France.
  • Alves A; NAMSA, Chasse sur Rhone, France.
  • Ladet S; Covidien - Sofradim Production, 116 Avenue du Formans - BP132, F-01600 Trevoux, France.
  • Lomanto D; Minimally Invasive Surgical Center, National University of Singapore, Singapore.
  • Bayon Y; Covidien - Sofradim Production, 116 Avenue du Formans - BP132, F-01600 Trevoux, France.
Int J Surg ; 22: 46-53, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26277532

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Telas Cirúrgicas / Hérnia Abdominal / Herniorrafia Tipo de estudo: Prognostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2015 Tipo de documento: Article