Your browser doesn't support javascript.
loading
Sonography of chondral print on humeral head.
Zappia, Marcello; Carfora, Michela; Romano, Alfonso Maria; Reginelli, Alfonso; Brunese, Luca; Rotondo, Antonio; Castagna, Alessandro.
Afiliação
  • Zappia M; Dipartimento di Medicina e di Scienze della Salute, Università degli Studi del Molise, Campobasso, Italy. marcellozappia1@tin.it.
  • Carfora M; Diagnostica Amato, San Marcellino, CE, Italy.
  • Romano AM; Campolongo Hospital, Marina di Eboli, SA, Italy.
  • Reginelli A; Dipartimento Magrassi-Lanzara, Seconda Università degli Studi di Napoli, Napoli, Italy.
  • Brunese L; Dipartimento di Medicina e di Scienze della Salute, Università degli Studi del Molise, Campobasso, Italy.
  • Rotondo A; Dipartimento Magrassi-Lanzara, Seconda Università degli Studi di Napoli, Napoli, Italy.
  • Castagna A; Humanitas Research Hospital, Rozzano, Milan, Italy.
Skeletal Radiol ; 45(1): 35-40, 2016 Jan.
Article em En | MEDLINE | ID: mdl-26298103
ABSTRACT

OBJECTIVE:

The aim of this study is to determine the diagnostic accuracy of sonography in order to identify the chondral print on the humeral head. MATERIALS AND

METHODS:

In total, 44 patients who had already been candidates for arthroscopic surgery were prospectively studied with ultrasound to assess the presence of humeral subchondral erosion at the level of the biceps pulley; no patient had undergone previous surgery or radiographic calcification of rotator cuff tendons. Using arthroscopy as the reference standard the sensitivity, specificity, positive predictive, negative predictive and diagnostic accuracy values were calculated.

RESULTS:

Of the 44 patients, arthroscopy showed the humeral chondral print in 30 patients. Of the 30 arthroscopy proven humeral chondral prints, ultrasound identified 28 subchondral erosions at the same level, with two false negatives. One of the 14 patients without arthroscopic humeral chondral print was positive for subchondral erosion at ultrasound. The sensitivity, specificity, positive predictive, negative predictive, and diagnostic accuracy values of ultrasound were respectively of 93, 93, 96, 87 and 93%.

CONCLUSION:

Ultrasound has a good diagnostic accuracy in identifying the chondral print sign.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Luxação do Ombro / Tendões / Ultrassonografia / Tendinopatia / Cabeça do Úmero / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Luxação do Ombro / Tendões / Ultrassonografia / Tendinopatia / Cabeça do Úmero / Instabilidade Articular Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article