Your browser doesn't support javascript.
loading
In vivo brain rosette spectroscopic imaging (RSI) with LASER excitation, constant gradient strength readout, and automated LCModel quantification for all voxels.
Schirda, Claudiu V; Zhao, Tiejun; Andronesi, Ovidiu C; Lee, Yoojin; Pan, Jullie W; Mountz, James M; Hetherington, Hoby P; Boada, Fernando E.
Afiliação
  • Schirda CV; University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, Pennsylvania, USA.
  • Zhao T; Siemens Healthcare, Siemens Medical Solutions USA, Inc., Pittsburgh, Pennsylvania, USA.
  • Andronesi OC; Massachusetts General Hospital, Department of Radiology, Boston, Massachusetts, USA.
  • Lee Y; University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, Pennsylvania, USA.
  • Pan JW; University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, Pennsylvania, USA.
  • Mountz JM; University of Pittsburgh School of Medicine, Department of Neurology, Pittsburgh, Pennsylvania, USA.
  • Hetherington HP; University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, Pennsylvania, USA.
  • Boada FE; University of Pittsburgh School of Medicine, Department of Radiology, Pittsburgh, Pennsylvania, USA.
Magn Reson Med ; 76(2): 380-90, 2016 08.
Article em En | MEDLINE | ID: mdl-26308482
PURPOSE: To optimize the Rosette trajectories for high-sensitivity in vivo brain spectroscopic imaging and reduced gradient demands. METHODS: Using LASER localization, a rosette based sampling scheme for in vivo brain spectroscopic imaging data on a 3 Tesla (T) system is described. The two-dimensional (2D) and 3D rosette spectroscopic imaging (RSI) data were acquired using 20 × 20 in-plane resolution (8 × 8 mm(2) ), and 1 (2D) -18 mm (1.1 cc) or 12 (3D) -8 mm partitions (0.5 cc voxels). The performance of the RSI acquisition was compared with a conventional spectroscopic imaging (SI) sequence using LASER localization and 2D or 3D elliptical phase encoding (ePE). Quantification of the entire RSI data set was performed using an LCModel based pipeline. RESULTS: The RSI acquisitions took 32 s for the 2D scan, and as short as 5 min for the 3D 20 × 20 × 12 scan, using a maximum gradient strength Gmax=5.8 mT/m and slew-rate Smax=45 mT/m/ms. The Bland-Altman agreement between RSI and ePE CSI, characterized by the 95% confidence interval for their difference (RSI-ePE), is within 13% of the mean (RSI+ePE)/2. Compared with the 3D ePE at the same nominal resolution, the effective RSI voxel size was three times smaller while the measured signal-to-noise ratio sensitivity, after normalization for differences in effective size, was 43% greater. CONCLUSION: 3D LASER-RSI is a fast, high-sensitivity spectroscopic imaging sequence, which can acquire medium-to-high resolution SI data in clinically acceptable scan times (5-10 min), with reduced stress on the gradient system. Magn Reson Med 76:380-390, 2016. © 2015 Wiley Periodicals, Inc.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Encéfalo / Química Encefálica / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Imagem Molecular / Lasers Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Encéfalo / Química Encefálica / Reconhecimento Automatizado de Padrão / Interpretação de Imagem Assistida por Computador / Imagem Molecular / Lasers Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article