Your browser doesn't support javascript.
loading
NEXT-GENERATION DUAL-BORE CANNULA FOR INJECTION OF VITAL DYES AND HEAVY LIQUIDS DURING PARS PLANA VITRECTOMY.
Toygar, Okan; Berrocal, Maria H; Charles, Martin; Riemann, Christopher D.
Afiliação
  • Toygar O; *Department of Ophthalmology, Cincinnati Eye Institute, University of Cincinnati School of Medicine, Cincinnati, Ohio; †Department of Ophthalmology, Bahcesehir University Faculty of Medicine, Istanbul, Turkey; ‡University of Puerto Rico School of Medicine, San Juan, Puerto Rico; and §Universidad del Salvador, Centro Oftalmológico Dr. Charles, Buenos Aires, Argentina.
Retina ; 36(3): 582-7, 2016 Mar.
Article em En | MEDLINE | ID: mdl-26383713
ABSTRACT

PURPOSE:

The objective of this study was to introduce and validate a next-generation dual bore cannula for microincisional vitrectomy surgery.

METHODS:

The SideFlo cannula with a closed tip and four vent ports on the sides was designed and manufactured. The cannula is designed to inject vital dyes for macular staining and perfluorocarbon liquids. Injection and venting properties were assessed subjectively in vivo, and venting was quantified in a plastic eye model system; 23-, 25-, and 27-gauge SideFlo cannulas were assessed and compared with existing axial dual bore cannula designs.

RESULTS:

The SideFlo cannula created a broad fan-like egress of fluid that was perpendicular to the axial direction of the cannula and eliminated the possibility for retinal fluid jet damage. Enhanced outflow venting was clinically relevant in terms of smoother injection experience and less intraocular pressure rise when compared with previous dual bore designs. Testing in a model eye system confirmed marked improvement in passive outflow compared with the first-generation dual bore cannula single vent port design for all gauges.

CONCLUSION:

The SideFlo cannula represents a novel next-generation dual bore cannula design with significantly improved performance over first-generation dual bore cannulas. Axial jet damage from fluid injection is eliminated, and pressure equilibration by passive venting from the eye is significantly enhanced.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitrectomia / Cateterismo / Corantes / Catéteres / Fluorocarbonos / Verde de Indocianina Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vitrectomia / Cateterismo / Corantes / Catéteres / Fluorocarbonos / Verde de Indocianina Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article