Your browser doesn't support javascript.
loading
Comparison of Subcuticular Suture Materials in Cesarean Skin Closure.
Hasdemir, Pinar Solmaz; Guvenal, Tevfik; Ozcakir, Hasan Tayfun; Koyuncu, Faik Mumtaz; Dinc Horasan, Gonul; Erkan, Mustafa; Oruc Koltan, Semra.
Afiliação
  • Hasdemir PS; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
  • Guvenal T; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
  • Ozcakir HT; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
  • Koyuncu FM; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
  • Dinc Horasan G; Department of Statistics, Celal Bayar University Medical School, Manisa, Turkey.
  • Erkan M; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
  • Oruc Koltan S; Department of Obstetrics and Gynecology, Celal Bayar University Medical School, 45000 Manisa, Turkey.
Surg Res Pract ; 2015: 141203, 2015.
Article em En | MEDLINE | ID: mdl-26413566
ABSTRACT
Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2015 Tipo de documento: Article