The evaluation of 7 commercial real-time PCR kits for Zaire ebolavirus using virus-like particle-encapsulated EBOV RNA.
Diagn Microbiol Infect Dis
; 83(4): 355-8, 2015 Dec.
Article
em En
| MEDLINE
| ID: mdl-26431829
Several Chinese commercial real-time PCR kits for Zaire ebolavirus have been developed after the Ebola outbreak and used by Chinese medical teams in West Africa. In order to know the essential performance indicators of these kits, analytical sensitivity and precision were evaluated with virus-like particle (VLP)-encapsulated EBOV RNA. The limit of detection (LOD) and the precision were completed with a series of VLPs. The maximum and minimum of LOD was acquired by ZJ BioTech and Daan gene, respectively. For precision, all of the detection results were <5% except the maximum 5.17%. Among them, Puruikang, Daan gene, Sansure, ZJ BioTech, and Huada demonstrated superior reproducibility. Overall, the requirements of LOD <1000 copies/mL and coefficient of variation <5% could be satisfied by all kits except Kehua. Meanwhile, it is feasible for VLPs as a substitute of positive samples in assay evaluation.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Kit de Reagentes para Diagnóstico
/
RNA Viral
/
Doença pelo Vírus Ebola
/
Técnicas de Diagnóstico Molecular
/
Ebolavirus
/
Reação em Cadeia da Polimerase em Tempo Real
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
Limite:
Humans
País/Região como assunto:
Africa
Idioma:
En
Ano de publicação:
2015
Tipo de documento:
Article