A highly sensitive and selective fluorescent probe for fluoride anions based on intramolecular charge transfer.
Liu, Jingkai; Xu, Zhenghe; Liu, Caiyun; Xu, Lirong; Wang, Zhongpeng; Zhu, Baocun.
Afiliação
  • Liu J; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
  • Xu Z; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
  • Liu C; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
  • Xu L; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
  • Wang Z; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
  • Zhu B; School of Resources and Environment, University of Jinan, Shandong Provincial Engineering Technology Research Center for Ecological Carbon Sink and Capture Utilization, Jinan, China.
Luminescence ; 31(5): 1166-70, 2016 Aug.
Article em En | MEDLINE | ID: mdl-26467672
Currently, there is a great need to develop methods for the selective detection of fluoride anions (F(-) ) owing to their toxicity in the environment and biological function in living systems. In this study, we developed a new fluorescent probe (probe 1) employing a Si-O bond as a highly selective recognition receptor for detecting F(-) via intramolecular charge transfer. Probe 1 could detect F(-) quantitatively using the turn-on fluorescence spectroscopy method with excellent sensitivity in the range of 4-38 µM and a detection limit of 0.26 µM; the detection time was < 17 min. We anticipate that probe 1 would be used widely to monitor F(-) in the environment. Copyright © 2015 John Wiley & Sons, Ltd.