Mitral valve repair after annuloplasty ring dehiscence using MitraClip.
Catheter Cardiovasc Interv
; 88(2): 301-6, 2016 Aug.
Article
em En
| MEDLINE
| ID: mdl-26481729
ABSTRACT
Dehiscence of a surgical mitral annuloplasty ring for repair of functional mitral regurgitation (MR) is an infrequently reported complication that often manifests as recurrent MR and heart failure. Re-do mitral valve surgery to correct ring dehiscence may not be feasible for patients at high risk of operative mortality or serious morbidity. We report two cases of mitral annular ring dehiscence and severe mitral regurgitation in patients at prohibitive risk for re-do mitral valve surgery who were successfully treated with MitraClip. © 2015 Wiley Periodicals, Inc.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Falha de Prótese
/
Próteses Valvulares Cardíacas
/
Cateterismo Cardíaco
/
Implante de Prótese de Valva Cardíaca
/
Anuloplastia da Valva Mitral
/
Insuficiência da Valva Mitral
Tipo de estudo:
Etiology_studies
Limite:
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2016
Tipo de documento:
Article