Your browser doesn't support javascript.
loading
Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.
Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong.
Afiliação
  • Wei Z; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Xiong X; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Guo C; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Si X; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Zhao Y; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • He M; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Yang C; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Xu W; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Tang F; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Fang X; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Zhang S; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
  • Zhang X; Beijing Key Laboratory for Microanalytical Methods, Instrumentation, Department of Chemistry, Tsinghua University , Beijing 100084, P. R. China.
Anal Chem ; 87(22): 11242-8, 2015 Nov 17.
Article em En | MEDLINE | ID: mdl-26488206
ABSTRACT
We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Orgânicos / Cebolas / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Orgânicos / Cebolas / Espectrometria de Massas por Ionização por Electrospray Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Ano de publicação: 2015 Tipo de documento: Article