Your browser doesn't support javascript.
loading
Enumeration of residual white blood cells in leukoreduced blood products: Comparing flow cytometry with a portable microscopic cell counter.
Castegnaro, Silvia; Dragone, Patrizia; Chieregato, Katia; Alghisi, Alberta; Rodeghiero, Francesco; Astori, Giuseppe.
Afiliação
  • Castegnaro S; Advanced Cellular Therapy Laboratory, Department of Cellular Therapy and Hematology, San Bortolo Hospital, Via Rodolfi 37, 36100 Vicenza, Italy; Hematology Project Foundation, Contrà S. Francesco 41, Vicenza, Italy.
  • Dragone P; Immunohematology and Transfusion Medicine Service, Department of Transfusion Medicine, San Bortolo Hospital, Vicenza, Italy.
  • Chieregato K; Advanced Cellular Therapy Laboratory, Department of Cellular Therapy and Hematology, San Bortolo Hospital, Via Rodolfi 37, 36100 Vicenza, Italy; Hematology Project Foundation, Contrà S. Francesco 41, Vicenza, Italy.
  • Alghisi A; Immunohematology and Transfusion Medicine Service, Department of Transfusion Medicine, San Bortolo Hospital, Vicenza, Italy.
  • Rodeghiero F; Advanced Cellular Therapy Laboratory, Department of Cellular Therapy and Hematology, San Bortolo Hospital, Via Rodolfi 37, 36100 Vicenza, Italy; Hematology Project Foundation, Contrà S. Francesco 41, Vicenza, Italy.
  • Astori G; Advanced Cellular Therapy Laboratory, Department of Cellular Therapy and Hematology, San Bortolo Hospital, Via Rodolfi 37, 36100 Vicenza, Italy. Electronic address: astori@hemato.ven.it.
Transfus Apher Sci ; 54(2): 266-70, 2016 Apr.
Article em En | MEDLINE | ID: mdl-26515432
ABSTRACT
Transfusion of blood components is potentially associated to the risk of cell-mediated adverse events and current guidelines require a reduction of residual white blood cells (rWBC) below 1 × 10(6) WBC/unit. The reference method to enumerate rare events is the flow cytometry (FCM). The ADAM-rWBC microscopic cell counter has been proposed as an alternative it measures leukocytes after their staining with propidium iodide. We have tested the Adam-rWBC for the ability to enumerate rWBC in red blood cells and concentrates. We have validated the flow cytometry (FCM) for linearity, precision accuracy and robustness and then the ADAM-rWBC results have been compared with the FCM. Our data confirm the linearity, accuracy, precision and robustness of the FCM. The ADAM-rWBC has revealed an adequate precision and accuracy. Even if the Bland-Altman analysis of the paired data has indicated that the two systems are comparable, it should be noted that the rWBC values obtained by the ADAM-rWBC were significantly higher compared to FCM. In conclusion, the Adam-rWBC cell counter could represent an alternative where FCM technology expertise is not available, even if the risk that borderline products could be misclassified exists.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Redução de Leucócitos / Citometria de Fluxo / Leucócitos Limite: Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Redução de Leucócitos / Citometria de Fluxo / Leucócitos Limite: Female / Humans / Male Idioma: En Ano de publicação: 2016 Tipo de documento: Article