Your browser doesn't support javascript.
loading
Fabrication of transparent SERS platform via interface self-assembly of gold nanorods and gel trapping technique for on-site real time detection.
Lin, Xiang; Hasi, Wu-Li-Ji; Han, Si-Qin-Gao-Wa; Lou, Xiu-Tao; Lin, Dian-Yang; Lu, Zhi-Wei.
Afiliação
  • Lin X; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. hasiwuliji@126.com dianyanglin@hit.edu.cn zw_lu@sohu.com.
  • Hasi WL; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. hasiwuliji@126.com dianyanglin@hit.edu.cn zw_lu@sohu.com.
  • Han SQ; Affiliated Hospital of Inner Mongolia University for the Nationalities, Tongliao, 028007, Inner Mongolia, China.
  • Lou XT; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. hasiwuliji@126.com dianyanglin@hit.edu.cn zw_lu@sohu.com.
  • Lin DY; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. hasiwuliji@126.com dianyanglin@hit.edu.cn zw_lu@sohu.com.
  • Lu ZW; National Key Laboratory of Science and Technology on Tunable Laser, Harbin Institute of Technology, Harbin, 150080, China. hasiwuliji@126.com dianyanglin@hit.edu.cn zw_lu@sohu.com.
Phys Chem Chem Phys ; 17(46): 31324-31, 2015 Dec 14.
Article em En | MEDLINE | ID: mdl-26556757
ABSTRACT
A transparent SERS platform was fabricated via the gel-trapping method coupled with a liquid/liquid interface self-assembly technique. We employed gold nanorods as the building blocks for interface self-assembly because of their strong localized surface plasmons upon excitation by infrared radiation. Based on a "top cover" configuration, this transparent SERS platform endows high signal reproducibility for directly detecting liquid samples by confining the sample droplet into a regular shape. The Au NR PDMS platform was able to directly detect crystal violet in aqueous solutions down to 10 ppb level with high enhancement factor (0.87 × 10(5)) and signal uniformity (RSD = 3.9%). Furthermore, SERS-based anti-fungal agent detection on a fish scale was demonstrated by simply covering the fish scale with a tailored GNRs PDMS film. The experimental results clearly show that the Au NR PDMS SERS platform has great potential for on-site real time detection of contaminants in water as well as on curved surfaces.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article