Your browser doesn't support javascript.
loading
Indoor Environmental Quality in Mechanically Ventilated, Energy-Efficient Buildings vs. Conventional Buildings.
Wallner, Peter; Munoz, Ute; Tappler, Peter; Wanka, Anna; Kundi, Michael; Shelton, Janie F; Hutter, Hans-Peter.
Afiliação
  • Wallner P; Institute of Environmental Health, Center for Public Health, Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria. peter.wallner4@gmail.com.
  • Munoz U; Austrian Institute for Healthy and Ecological Building, Alserbachstraße 5, Vienna 1090, Austria. office@innenraumanalytik.at.
  • Tappler P; Austrian Institute for Healthy and Ecological Building, Alserbachstraße 5, Vienna 1090, Austria. p.tappler@innenraumanalytik.at.
  • Wanka A; Institute of Sociology, University Vienna, Austria, Alserbachstraße 5, Vienna 1090, Austria. anna.wanka@univie.ac.at.
  • Kundi M; Institute of Environmental Health, Center for Public Health, Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria. michael.kundi@meduniwien.ac.at.
  • Shelton JF; Institute of Environmental Health, Center for Public Health, Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria. janie.shelton@gmail.com.
  • Hutter HP; Institute of Environmental Health, Center for Public Health, Medical University Vienna, Kinderspitalgasse 15, Vienna 1090, Austria. hans-peter.hutter@meduniwien.ac.at.
Int J Environ Res Public Health ; 12(11): 14132-47, 2015 Nov 06.
Article em En | MEDLINE | ID: mdl-26561823
Energy-efficient buildings need mechanical ventilation. However, there are concerns that inadequate mechanical ventilation may lead to impaired indoor air quality. Using a semi-experimental field study, we investigated if exposure of occupants of two types of buildings (mechanical vs. natural ventilation) differs with regard to indoor air pollutants and climate factors. We investigated living and bedrooms in 123 buildings (62 highly energy-efficient and 61 conventional buildings) built in the years 2010 to 2012 in Austria (mainly Vienna and Lower Austria). Measurements of indoor parameters (climate, chemical pollutants and biological contaminants) were conducted twice. In total, more than 3000 measurements were performed. Almost all indoor air quality and room climate parameters showed significantly better results in mechanically ventilated homes compared to those relying on ventilation from open windows and/or doors. This study does not support the hypothesis that occupants in mechanically ventilated low energy houses are exposed to lower indoor air quality.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ventilação / Poluição do Ar em Ambientes Fechados / Conservação de Recursos Energéticos Limite: Animals País/Região como assunto: Europa Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ventilação / Poluição do Ar em Ambientes Fechados / Conservação de Recursos Energéticos Limite: Animals País/Região como assunto: Europa Idioma: En Ano de publicação: 2015 Tipo de documento: Article