Your browser doesn't support javascript.
loading
Microchamber arrays with an integrated long luminescence lifetime pH sensor.
Poehler, Elisabeth; Pfeiffer, Simon A; Herm, Marc; Gaebler, Michael; Busse, Benedikt; Nagl, Stefan.
Afiliação
  • Poehler E; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Pfeiffer SA; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Herm M; SYNTHON Chemicals, Werkstattstraße 10, 06766, Wolfen, Germany.
  • Gaebler M; SYNTHON Chemicals, Werkstattstraße 10, 06766, Wolfen, Germany.
  • Busse B; zell-kontakt GmbH, Industriestrasse 3, 37176, Nörten-Hardenberg, Germany.
  • Nagl S; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany. nagl@chemie.uni-leipzig.de.
Anal Bioanal Chem ; 408(11): 2927-35, 2016 Apr.
Article em En | MEDLINE | ID: mdl-26590561
ABSTRACT
A pH probe with a microsecond luminescence lifetime was obtained via covalent coupling of 6-carboxynaphthofluorescein (CNF) moieties to ruthenium-tris-(1,10-phenanthroline)(2+). The probe was covalently attached to amino-modified poly-(2-hydroxyethyl)methacrylate (pHEMA) and showed a pH-dependent FRET with luminescence lifetimes of 681 to 1260 ns and a working range from ca. pH 6.5 to 9.0 with a pKa of 7.79 ± 0.14. The pH sensor matrix was integrated via spin coating as ca. 1- to 2-µm-thick layer into "CytoCapture" cell culture dishes of 6 mm in diameter. These contained a microcavity array of square-shaped regions of 40 µm length and width and 15 µm depth that was homogeneously coated with the pH sensor matrix. The sensor layer showed fast response times in both directions. A microscopic setup was developed that enabled imaging of the pH inside the microchamber arrays over many hours. As a proof of principle, we monitored the pH of Escherichia coli cell cultures grown in the microchamber arrays. The integrated sensor matrix allowed pH monitoring spatially resolved in every microchamber, and the differences in cell growth between individual chambers could be resolved and quantified.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Concentração de Íons de Hidrogênio Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Concentração de Íons de Hidrogênio Idioma: En Ano de publicação: 2016 Tipo de documento: Article