Your browser doesn't support javascript.
loading
The performance characteristics of prostate-specific antigen and prostate-specific antigen density in Chinese men.
Teoh, Jeremy Yc; Yuen, Steffi Kk; Tsu, James Hl; Wong, Charles Kw; Ho, Brian Sh; Ng, Ada Tl; Ma, Wai-Kit; Ho, Kwan-Lun; Yiu, Ming-Kwong.
Afiliação
  • Teoh JY; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Yuen SK; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Tsu JH; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Wong CK; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Ho BS; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Ng AT; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Ma WK; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Ho KL; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
  • Yiu MK; Division of Urology, Department of Surgery, Queen Mary Hospital, University of Hong Kong, Hong Kong, China.
Asian J Androl ; 19(1): 113-116, 2017.
Article em En | MEDLINE | ID: mdl-26620456
ABSTRACT
We investigated the performance characteristics of prostate-specific antigen (PSA) and PSA density (PSAD) in Chinese men. All Chinese men who underwent transrectal ultrasound-guided prostate biopsy (TRUS-PB) from year 2000 to 2013 were included. The receiver operating characteristic (ROC) curves for both PSA and PSAD were analyzed. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) at different cut-off levels were calculated. A total of 2606 Chinese men were included. For the ROC, the area under curve was 0.770 for PSA (P < 0.001) and 0.823 for PSAD (P < 0.001). PSA of 4.5 ng ml-1 had sensitivity of 94.4%, specificity of 14.1%, PPV of 29.5%, and NPV of 86.9%; PSAD of 0.12 ng ml-1 cc-1 had sensitivity of 94.5%, specificity of 26.6%, PPV of 32.8%, and NPV of 92.7%. On multivariate logistic regression analyses, PSA cut-off at 4.5 ng ml-1 (OR 1.61, 95% CI 1.05-2.45, P= 0.029) and PSAD cut-off at 0.12 ng ml-1 cc-1 (OR 6.22, 95% CI 4.20-9.22, P< 0.001) were significant predictors for prostate cancer detection on TRUS-PB. In conclusion, the performances of PSA and PSAD at different cut-off levels in Chinese men were very different from those in Caucasians. PSA of 4.5 ng ml-1 and PSAD of 0.12 ng ml-1 cc-1 had near 95% sensitivity and were significant predictors of prostate cancer detection in Chinese men.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Calicreínas / Antígeno Prostático Específico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Calicreínas / Antígeno Prostático Específico Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Aged / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Ano de publicação: 2017 Tipo de documento: Article