Your browser doesn't support javascript.
loading
Sensitive method for the determination of rocilinostat in small volume mouse plasma by LC-MS/MS and its application to a pharmacokinetic study in mice.
Gupta, Manish; Dixit, Abhishek; Devaraj, V C; Zainuddin, Mohd; Bhamidipati, Ravi Kanth; Hallur, Mahanandeesha S; Dewang, Purushottam; Rajagopal, Sridharan; Rajagopal, Sriram; Mullangi, Ramesh.
Afiliação
  • Gupta M; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Dixit A; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Devaraj VC; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Zainuddin M; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Bhamidipati RK; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Hallur MS; Department of Medicinal Chemistry, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Dewang P; Department of Medicinal Chemistry, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Rajagopal S; Department of Medicinal Chemistry, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Rajagopal S; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
  • Mullangi R; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Industrial Suburb, Yeshwanthpur, Bangalore, -560 022, India.
Biomed Chromatogr ; 30(7): 1138-1144, 2016 Jul.
Article em En | MEDLINE | ID: mdl-26633099
ABSTRACT
A highly sensitive, specific and rapid LC-ESI-MS/MS method has been developed and validated for the quantification of rocilinostat in small volume mouse plasma (20 µL) using vorinostat as an internal standard (IS) as per regulatory guidelines. Sample preparation was accomplished through a protein precipitation procedure with acetonitrile. Chromatography was achieved on Prodigy ODS-2 column using a binary gradient using mobile phase A (0.2% formic acid in water) and B (acetonitrile) at a flow rate of 0.38 mL/min. The total chromatographic run time was 4.1 min and the elution of rocilinostat and IS occurred at ~3.2 and 2.9 min, respectively. A linear response function was established in the concentration range of 0.28-1193 ng/mL in mouse plasma. The intra- and inter-day accuracy and precisions were in the ranges of 3.12-8.93 and 6.41-11.6%, respectively. This novel method has been applied to a pharmacokinetic study in mice. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pirimidinas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Ácidos Hidroxâmicos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pirimidinas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Ácidos Hidroxâmicos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article