Your browser doesn't support javascript.
loading
Photoacoustic Probes for Ratiometric Imaging of Copper(II).
Li, Hao; Zhang, Pamela; Smaga, Lukas P; Hoffman, Ryan A; Chan, Jefferson.
Afiliação
  • Li H; Roger Adams Laboratory, Department of Chemistry, University of Illinois , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.
  • Zhang P; Roger Adams Laboratory, Department of Chemistry, University of Illinois , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.
  • Smaga LP; Roger Adams Laboratory, Department of Chemistry, University of Illinois , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.
  • Hoffman RA; Roger Adams Laboratory, Department of Chemistry, University of Illinois , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.
  • Chan J; Roger Adams Laboratory, Department of Chemistry, University of Illinois , 600 South Mathews Avenue, Urbana, Illinois 61801, United States.
J Am Chem Soc ; 137(50): 15628-31, 2015 Dec 23.
Article em En | MEDLINE | ID: mdl-26652006
ABSTRACT
Photoacoustic tomography has emerged as a promising alternative to MRI and X-ray scans in the clinical setting due to its ability to afford high-resolution images at depths in the cm range. However, its utility has not been established in the basic research arena owing to a lack of analyte-specific photoacoustic probes. To this end, we have developed acoustogenic probes for copper(II)-1 and -2 (APC-1 and APC-2, a water-soluble congener) for the chemoselective visualization of Cu(II), a metal ion which plays a crucial role in chronic neurological disorders such as Alzheimer's disease. To detect Cu(II), we have equipped both APCs with a 2-picolinic ester sensing module that is readily hydrolyzed in the presence of Cu(II) but not by other divalent metal ions. Additionally, we designed APC-1 and APC-2 explicitly for ratiometric photoacoustic imaging by using an aza-BODIPY dye scaffold exhibiting two spectrally resolved NIR absorbance bands which correspond to the 2-picolinic ester capped and uncapped phenoxide forms. The normalized ratiometric turn-on responses for APC-1 and APC-2 were 89- and 101-fold, respectively.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acústica / Sondas Moleculares / Cobre Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Acústica / Sondas Moleculares / Cobre Idioma: En Ano de publicação: 2015 Tipo de documento: Article