The clinical outcome of cardiac resynchronization therapy in post-surgical valvular cardiomyopathy.
Leyva, Francisco; Umar, Fraz; Taylor, Robin J; Steeds, Richard P; Frenneaux, Michael P.
Afiliação
  • Leyva F; Aston Medical Research Institute, Aston Medical School, Aston Triangle, Birmingham, West Midlands B4 7ET, UK f.leyva@aston.ac.uk.
  • Umar F; Centre for Cardiovascular Sciences, University of Birmingham, Birmingham, UK.
  • Taylor RJ; Centre for Cardiovascular Sciences, University of Birmingham, Birmingham, UK.
  • Steeds RP; Centre for Cardiovascular Sciences, University of Birmingham, Birmingham, UK.
  • Frenneaux MP; Norwich Medical School, University of East Anglia, Norwich, UK.
Europace ; 18(5): 732-8, 2016 May.
Article em En | MEDLINE | ID: mdl-26802014
ABSTRACT

AIMS:

Trials have shown that cardiac resynchronization therapy (CRT) is effective in patients with 'non-ischaemic cardiomyopathy'. Patients with post-surgical valvular cardiomyopathy (PSVCM) have been excluded from such trials. We sought to compare the clinical outcome of CRT in patients with PSVCM, idiopathic dilated cardiomyopathy (IDCM), or ischaemic cardiomyopathy (ICM). METHODS AND

RESULTS:

Clinical events and response to CRT were quantified in 556 patients (PSVCM = 38; IDCM = 165; ICM = 353) over 4.52 years [median, inter-quartile range (IQR) 4.42]. Response to CRT was defined as survival for ≥1 year free of hospitalizations plus improvement by ≥1 NYHA class or ≥25% in 6-min walking distance. Cardiac resynchronization therapy was initiated at 5.86 years (median, IQR 9.86) after aortic valve replacement (73.7%) or mitral valve replacement/repair (44.7%). Compared with PSVCM, IDCM was associated with a lower total mortality [hazards ratio, HR 0.54 (95% confidence interval, CI 0.34-0.84)], cardiac mortality [HR 0.43 (95% CI 0.26-0.70)], and total mortality or major adverse cardiovascular events [HR 0.57 (95% CI 0.37-0.87)], independent of known confounders. Compared with PSVCM, ICM was associated with a similar risk of death from pump failure [HR 0.83 (95% CI 0.50-1.37)] and IDCM was associated with a lower risk [HR 0.46 (95% CI 0.26-0.82)]. Response to CRT was similar across the groups.

CONCLUSIONS:

Compared with IDCM, PSVCM was associated with a worse outcome after CRT. Outcomes from PSVCM were similar to ICM. These findings indicate that PSVCM behaves very differently to IDCM after CRT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Falha de Equipamento / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Cardiomiopatias Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desfibriladores Implantáveis / Falha de Equipamento / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Cardiomiopatias Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Ano de publicação: 2016 Tipo de documento: Article