Your browser doesn't support javascript.
loading
Evaluating the sensitivity, reproducibility and flexibility of a method to test hard shell capsules intended for use in dry powder inhalers.
Chong, Rosalind H E; Jones, Brian E; Díez, Fernando; Birchall, James C; Coulman, Sion A.
Afiliação
  • Chong RH; Cardiff School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom.
  • Jones BE; Cardiff School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom; Qualicaps Europe S.A.U., Alcobendas, Madrid, Spain.
  • Díez F; Qualicaps Europe S.A.U., Alcobendas, Madrid, Spain.
  • Birchall JC; Cardiff School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom.
  • Coulman SA; Cardiff School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff CF10 3NB, United Kingdom. Electronic address: coulmansa@cardiff.ac.uk.
Int J Pharm ; 500(1-2): 316-25, 2016 Mar 16.
Article em En | MEDLINE | ID: mdl-26806464
Pharmaceutical tests for hard shell capsules are designed for orally administered capsules. The use of capsules in dry powder inhalers is widespread and increasing and therefore more appropriate tests are required to ensure quality and determine if these capsules are fit for purpose. This study aims to determine the flexibility, reproducibility and sensitivity of a quantitative method that is designed to evaluate the puncture characteristics of different capsule shell formulations under different climatic conditions. A puncture testing method was used to generate force displacement curves for five capsule formulations that were stored and tested at two different temperatures (5°C and 19°C). Force-displacement puncture profiles were reproducible for individual capsule shell formulations. The methodology was able to discriminate between capsules produced using different primary materials i.e. gelatin versus hypromellose, as well as more minor changes to capsule formulation i.e. different material grades and excipients. Reduced temperature increased the forces required for capsule puncture however further work is required to confirm its significance. Results indicate the method provides a reproducible and sensitive means of evaluating capsule puncture. Future studies should validate the methodology at different test sites, using different operators and with different capsule shell formulations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cápsulas / Tecnologia Farmacêutica Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cápsulas / Tecnologia Farmacêutica Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article