Influence of Implant Neck Design on Bone Formation Under Mechanical Repetitive Loading: Histomorphometric and Microcomputed Tomographic Studies in Rabbit Tibiae.
Implant Dent
; 25(2): 171-8, 2016 Apr.
Article
em En
| MEDLINE
| ID: mdl-26807817
PURPOSE: The aim of this study was to investigate effects of implant neck design on the original concept of osseointegration and bone formation when applying mechanical repetitive loading by bone-integrated implants. MATERIALS AND METHODS: Twenty-eight anodized Ti-6Al-4V alloy implants with +60° or -60° grooves in the implant neck were placed in the proximal tibial metaphysis of 14 rabbits. Fourteen implants received mechanical repetitive loading along the long axis of the implant for 8 weeks at 12 weeks after implant placement. The remaining 14 implants received no loading. Histomorphometric and microcomputed tomographic analyses were then performed. RESULTS: No effect of neck design was observed without mechanical loading, whereas osseointegration around the +60° grooves was upregulated with mechanical loading. Calculated load effects on bone structure around the implant neck with +60° grooves were larger when compared with the -60° grooves under mechanical loading. CONCLUSIONS: These findings indicate that the establishment of osseointegration and bone formation around the implant neck with +60° grooves is superior to those with -60° grooves under loaded conditions.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Próteses e Implantes
/
Tíbia
/
Osseointegração
Limite:
Animals
Idioma:
En
Ano de publicação:
2016
Tipo de documento:
Article