Your browser doesn't support javascript.
loading
Stochastic detection and characterisation of individual ferrocene derivative tagged graphene nanoplatelets.
Wu, Haoyu; Lin, Qianqi; Batchelor-McAuley, Christopher; Gonçalves, Luís Moreira; Lima, Carlos F R A C; Compton, Richard G.
Afiliação
  • Wu H; Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, UK. richard.compton@chem.ox.ac.uk.
  • Lin Q; Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, UK. richard.compton@chem.ox.ac.uk.
  • Batchelor-McAuley C; Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, UK. richard.compton@chem.ox.ac.uk.
  • Gonçalves LM; LAQV-REQUIMTE, Departamento de Química e Bioquímica, Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007 Porto, Portugal.
  • Lima CF; CIQ, Departamendo de Química e Bioquímica, Faculdade de Ciências da Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007 Porto, Portugal and Department of Chemistry & QOPNA, University of Aveiro, Aveiro, Portugal.
  • Compton RG; Department of Chemistry, Physical and Theoretical Chemistry Laboratory, University of Oxford, South Parks Road, Oxford OX1 3QZ, UK. richard.compton@chem.ox.ac.uk.
Analyst ; 141(9): 2696-703, 2016 04 25.
Article em En | MEDLINE | ID: mdl-26830880
Graphene nanoplatelets (GNPs) are 'tagged' with 1-(biphen-4-yl)ferrocene. Chronoamperometry is then utilised to observe single particle impacts when GNPs suspended in solution collide with a carbon fibre micro wire electrode held at an oxidising potential, resulting in current/time transient "spikes". The impacts are associated with two types of charge transfer: Faradaic due to oxidation of the 'tag' and capacitative due to disruption of the double layer. Analysis of the spikes suggests approximate monolayer coverage of 1-(biphen-4-yl)ferrocene on the GNP surfaces, with a surface coverage of (2.2 ± 0.3) × 10(-10) mol cm(-2). In contrast non-derivatised ferrocene does not exhibit any significant adsorption on the GNP material.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article