Your browser doesn't support javascript.
loading
Statistical tools and control of internal lubricant content of inhalation grade HPMC capsules during manufacture.
Ayala, Guillermo; Díez, Fernando; Gassó, María T; Jones, Brian E; Martín-Portugués, Rafael; Ramiro-Aparicio, Juan.
Afiliação
  • Ayala G; Department of Statistics and O.R. University of Valencia, Avda. Vicent Andrés Estellés, 1, 46100 Burjasot, Spain. Electronic address: Guillermo.Ayala@uv.es.
  • Díez F; Qualicaps Europe, S.A.U., Avda. de Valdelatas 4, 28108 Alcobendas, Madrid, Spain. Electronic address: Fdiez@qualicaps.es.
  • Gassó MT; Institute of Multidisciplinar Mathematics and Department of Mathematics Polytechnical University of Valencia, Camino de Vera s/n, 46022 Valencia, Spain. Electronic address: mgasso@mat.upv.es.
  • Jones BE; School of Pharmacy & Pharmaceutical Sciences, Cardiff University, Cardiff, UK. Electronic address: JBE2@cardiff.ac.uk.
  • Martín-Portugués R; Qualicaps Europe, S.A.U., Avda. de Valdelatas 4, 28108 Alcobendas, Madrid, Spain. Electronic address: Rmartin-portugues@qualicaps.es.
  • Ramiro-Aparicio J; Qualicaps Europe, S.A.U., Avda. de Valdelatas 4, 28108 Alcobendas, Madrid, Spain. Electronic address: jraparicio@qualicaps.es.
Int J Pharm ; 503(1-2): 36-40, 2016 Apr 30.
Article em En | MEDLINE | ID: mdl-26899981
The internal lubricant content (ILC) of inhalation grade HPMC capsules is a key factor to ensure good powder release when the patient inhales a medicine from a dry powder inhaler (DPI). Powder release from capsules has been shown to be influenced by the ILC. The characteristics used to measure this are the emitted dose, fine particle fraction and mass median aerodynamic diameter. In addition the ILC level is critical for capsule shell manufacture because it is an essential part of the process that cannot work without it. An experiment has been applied to the manufacture of inhalation capsules with the required ILC. A full factorial model was used to identify the controlling factors and from this a linear model has been proposed to improve control of the process.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cápsulas / Modelos Estatísticos / Lubrificantes / Inaladores de Pó Seco Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cápsulas / Modelos Estatísticos / Lubrificantes / Inaladores de Pó Seco Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article