Magnetic Resonance Elastography: Measurement of Hepatic Stiffness Using Different Direct Inverse Problem Reconstruction Methods in Healthy Volunteers and Patients with Liver Disease.
Saito, Shigeyoshi; Tanaka, Keiko; Hashido, Takashi.
Afiliação
  • Saito S; Department of Medical Physics and Engineering, Division of Health Sciences, Osaka University, Graduate School of Medicine.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(2): 128-38, 2016 02.
Article em Ja | MEDLINE | ID: mdl-26902377
ABSTRACT
The purpose of this study was to compare the mean hepatic stiffness values obtained by the application of two different direct inverse problem reconstruction methods to magnetic resonance elastography (MRE). Thirteen healthy men (23.2±2.1 years) and 16 patients with liver diseases (78.9±4.3 years; 12 men and 4 women) were examined for this study using a 3.0 T-MRI. The healthy volunteers underwent three consecutive scans, two 70-Hz waveform and a 50-Hz waveform scans. On the other hand, the patients with liver disease underwent scanning using the 70-Hz waveform only. The MRE data for each subject was processed twice for calculation of the mean hepatic stiffness (Pa), once using the multiscale direct inversion (MSDI) and once using the multimodel direct inversion (MMDI). There were no significant differences in the mean stiffness values among the scans obtained with two 70-Hz and different waveforms. However, the mean stiffness values obtained with the MSDI technique (with mask 2895.3±255.8 Pa, without mask 2940.6±265.4 Pa) were larger than those obtained with the MMDI technique (with mask 2614.0±242.1 Pa, without mask 2699.2±273.5 Pa). The reproducibility of measurements obtained using the two techniques was high for both the healthy volunteers [intraclass correlation coefficients (ICCs) 0.840-0.953] and the patients (ICC 0.830-0.995). These results suggest that knowledge of the characteristics of different direct inversion algorithms is important for longitudinal liver stiffness assessments such as the comparison of different scanners and evaluation of the response to fibrosis therapy.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Humans / Male / Middle aged Idioma: Ja Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Técnicas de Imagem por Elasticidade / Hepatopatias Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Humans / Male / Middle aged Idioma: Ja Ano de publicação: 2016 Tipo de documento: Article