Your browser doesn't support javascript.
loading
A surface acoustic wave (SAW)-enhanced grating-coupling phase-interrogation surface plasmon resonance (SPR) microfluidic biosensor.
Sonato, A; Agostini, M; Ruffato, G; Gazzola, E; Liuni, D; Greco, G; Travagliati, M; Cecchini, M; Romanato, F.
Afiliação
  • Sonato A; CNR-IOM, Area Science Park, S.S. 14, km 163.5, 34149, Basovizza (TS), Italy.
  • Agostini M; NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy. marco.cecchini@nano.cnr.it and Center for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro 12, 56127 Pisa, Italy.
  • Ruffato G; Department of Physics and Astronomy, University of Padova, Via Marzolo 8, 35131 Padova, Italy.
  • Gazzola E; Department of Physics and Astronomy, University of Padova, Via Marzolo 8, 35131 Padova, Italy.
  • Liuni D; Department of Physics and Astronomy, University of Padova, Via Marzolo 8, 35131 Padova, Italy.
  • Greco G; NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy. marco.cecchini@nano.cnr.it.
  • Travagliati M; NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy. marco.cecchini@nano.cnr.it and Center for Nanotechnology Innovation@NEST, Istituto Italiano di Tecnologia, Piazza San Silvestro 12, 56127 Pisa, Italy.
  • Cecchini M; NEST, Istituto Nanoscienze-CNR and Scuola Normale Superiore, Piazza San Silvestro 12, 56127 Pisa, Italy. marco.cecchini@nano.cnr.it.
  • Romanato F; CNR-IOM, Area Science Park, S.S. 14, km 163.5, 34149, Basovizza (TS), Italy and Department of Physics and Astronomy, University of Padova, Via Marzolo 8, 35131 Padova, Italy.
Lab Chip ; 16(7): 1224-33, 2016 Apr 07.
Article em En | MEDLINE | ID: mdl-26932784
A surface acoustic wave (SAW)-enhanced, surface plasmon resonance (SPR) microfluidic biosensor in which SAW-induced mixing and phase-interrogation grating-coupling SPR are combined in a single lithium niobate lab-on-a-chip is demonstrated. Thiol-polyethylene glycol adsorption and avidin/biotin binding kinetics were monitored by exploiting the high sensitivity of grating-coupling SPR under azimuthal control. A time saturation binding kinetics reduction of 82% and 24% for polyethylene and avidin adsorption was obtained, respectively, due to the fluid mixing enhancement by means of the SAW-generated chaotic advection. These results represent the first implementation of a nanostructured SAW-SPR microfluidic biochip capable of significantly improving the molecule binding kinetics on a single, portable device. In addition, the biochip here proposed is suitable for a great variety of biosensing applications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Som / Ressonância de Plasmônio de Superfície / Dispositivos Lab-On-A-Chip Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Som / Ressonância de Plasmônio de Superfície / Dispositivos Lab-On-A-Chip Idioma: En Ano de publicação: 2016 Tipo de documento: Article