Your browser doesn't support javascript.
loading
Improved sensitivity of an acid sphingomyelinase activity assay using a C6:0 sphingomyelin substrate.
Chuang, Wei-Lien; Pacheco, Joshua; Cooper, Samantha; Kingsbury, Jonathan S; Hinds, John; Wolf, Pavlina; Oliva, Petra; Keutzer, Joan; Cox, Gerald F; Zhang, Kate.
Afiliação
  • Chuang WL; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Pacheco J; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Cooper S; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Kingsbury JS; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Hinds J; Northeastern University, 360 Huntington Avenue, Boston, MA 02115, USA.
  • Wolf P; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Oliva P; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Keutzer J; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
  • Cox GF; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA; Division of Genetics, Boston Children's Hospital, 300 Longwood Avenue, Boston, MA 02115, USA.
  • Zhang K; Genzyme Corporation, a Sanofi Company, One Mountain Road, Framingham, MA 01701-9322, USA.
Mol Genet Metab Rep ; 3: 55-7, 2015 Jun.
Article em En | MEDLINE | ID: mdl-26937397
ABSTRACT
Short-chain C6-sphingomyelin is an artificial substrate that was used in an acid sphingomyelinase activity assay for a pilot screening study of patients with Niemann-Pick disease types A and B. Using previously published multiplex and single assay conditions, normal acid sphingomyelinase activity levels (i.e. false negative results) were observed in two sisters with Niemann-Pick B who were compound heterozygotes for two missense mutations, p.C92W and p.P184L, in the SMPD1 gene. Increasing the sodium taurocholate detergent concentration in the assay buffer lowered the activity levels of these two patients into the range observed with other patients with clear separation from normal controls.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2015 Tipo de documento: Article