Closure of the annulus fibrosus of the intervertebral disc using a novel suture application device-in vivo porcine and ex vivo biomechanical evaluation.
Spine J
; 16(7): 889-95, 2016 07.
Article
em En
| MEDLINE
| ID: mdl-26972621
BACKGROUND CONTEXT: Defects in the annulus fibrosus (AF) remain a challenge in the surgical treatment of lumbar disc herniations with persistent defects, allowing potential re herniation of nucleus pulposus (NP) tissue. A cervical porcine model was chosen to simulate human lumbar intervertebral disc (IVD). PURPOSE: The aim of this study was to determine the technical feasibility of closure of the AF of the IVD using a novel minimally invasive Kerrison-shaped suture application device. STUDY DESIGN: Ex vivo biomechanical and in vivo porcine device evaluations were performed. METHODS: Ex vivo biomechanical evaluation: 15 porcine spinal units were explanted and subjected to mock discectomy. The annular defect was closed using 2-0 non-absorbable (ultra-high molecular-weight polyethylene, UHMWPE) suture and Dines knot. The knot was backed up with two, three, or four throws. The spinal unit was subject to 4000 cycles of flexion/extension with 1500 N of axial load, and assessed for knot slippage. In vivo porcine device evaluation: three pigs (53-57 kg) were anesthetized and underwent a ventral surgical approach to the cervical spine. The AF of two discs was incised, and simulated partial NP discectomy was performed. The defect was closed at one level using the AnchorKnot device to apply the suture with a Dines knot and four throws. The pigs were observed for 4 weeks before euthanasia, allowing 7T magnetic resonance imaging (MRI) and histological evaluation. RESULTS: A Dines knot with four throws experienced no slippage after 4000 cycles. This configuration was tested in vivo. Clinically, the neurological examination in treated pigs was normal following surgery. Histological and MRI assessment confirmed sustained defect closure at 4 weeks. There was no reaction to the suture material and no NP extrusion at any of the sutured levels. CONCLUSIONS: This study demonstrates that it is technically feasible to perform AF defect closure in a porcine model. This novel device achieved AF defect closure that was maintained through 4 weeks in vivo.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Instrumentos Cirúrgicos
/
Suturas
/
Discotomia
/
Anel Fibroso
Tipo de estudo:
Evaluation_studies
Limite:
Animals
Idioma:
En
Ano de publicação:
2016
Tipo de documento:
Article