Your browser doesn't support javascript.
loading
A novel immunochromatographic assay based on a time-resolved chemiluminescence strategy for the multiplexed detection of ractopamine and clenbuterol.
Wang, Wenwen; Su, Xiaoxiao; Ouyang, Hui; Wang, Lin; Fu, Zhifeng.
Afiliação
  • Wang W; Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
  • Su X; Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
  • Ouyang H; Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
  • Wang L; Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China.
  • Fu Z; Key Laboratory of Luminescence and Real-Time Analytical Chemistry, Ministry of Education, College of Pharmaceutical Sciences, Southwest University, Chongqing 400716, China. Electronic address: fuzf@swu.edu.cn.
Anal Chim Acta ; 917: 79-84, 2016 Apr 21.
Article em En | MEDLINE | ID: mdl-27026603
A novel multiplexed immunochromatographic assay (ICA) based on a time-resolved chemiluminescence (CL) strategy was developed for quantitative detection of ß-agonists, by utilizing ractopamine (RAC) and clenbuterol (CLE) as the models. Different from conventional multiplexed ICA methods which usually require two or more test lines, this strategy was developed for detection of two ß-agonists by using only one test line on the nitrocellulose membrane. In this study, horseradish peroxidase and alkaline phosphatase were used as the signal probes to label RAC antibody and CLE antibody, respectively. The two CL reactions with flash type and glow type kinetics characteristics were triggered simultaneously by injecting the coreactants, then the signals for RAC and CLE detections were recorded at 3 s and 300 s after coreactants injection, respectively. Owing to the utilization of CL detection, this protocol showed ideal sensitivity for quantitation. Under the optimal conditions, the detection limits for RAC and CLE were 0.17 ng mL(-1) and 0.067 ng mL(-1) (S/N = 3), respectively. The whole assay process can be accomplished within 20 min without complicated sample pretreatment. The proposed method was successfully applied for the detection of RAC and CLE in spiked swine urine. It opens up a new pathway for designing a low cost, time-efficiency and multiplexed strategy for rapid screening and field assay.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenetilaminas / Cromatografia de Afinidade / Clembuterol / Agonistas Adrenérgicos beta Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fenetilaminas / Cromatografia de Afinidade / Clembuterol / Agonistas Adrenérgicos beta Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article