Your browser doesn't support javascript.
loading
A new model of implant-related osteomyelitis in the metaphysis of rat tibiae.
Harrasser, Norbert; Gorkotte, Johannes; Obermeier, Andreas; Feihl, Susanne; Straub, Melanie; Slotta-Huspenina, Julia; von Eisenhart-Rothe, Ruediger; Moser, Walter; Gruner, Philipp; de Wild, Michael; Gollwitzer, Hans; Burgkart, Rainer.
Afiliação
  • Harrasser N; Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany. norbert.harrasser@outlook.de.
  • Gorkotte J; Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Obermeier A; Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Feihl S; Institute for Medical Microbiology and Immunology, Technical University of Munich, Trogerstr. 30, 81675, Munich, Germany.
  • Straub M; Institute of Pathology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Slotta-Huspenina J; Institute of Pathology, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • von Eisenhart-Rothe R; Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Moser W; Atesos medical AG, Schachenallee 29, CH-5000, Aarau, Switzerland.
  • Gruner P; Medicoat AG, Almuesenacherstrasse 2a, CH-5506, Maegenwil, Switzerland.
  • de Wild M; University of Applied Sciences and Arts Northwestern Switzerland (FHNW), School of Life Sciences, CH-4132, Muttenz, Switzerland.
  • Gollwitzer H; Clinic of Orthopedics and Sports Orthopedics, Klinikum rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675, Munich, Germany.
  • Burgkart R; ATOS Clinic, Effnerstr.38, 81925, Munich, Germany.
BMC Musculoskelet Disord ; 17: 152, 2016 Apr 08.
Article em En | MEDLINE | ID: mdl-27060078
ABSTRACT

BACKGROUND:

Animal models serve as an important tool to understand peri-implant infection. Most of the models use high bacterial loads (>10(4) colony forming units, CFU) to provide high infection rates. Therefore these animals evolve rather similarly, making comparison between groups and statistical analysis possible. On the other hand, to mimic clinical constellation of surgery-related infections the use of low amounts of bacteria would be more advantageous.

METHODS:

We developed a metaphyseal rat model of peri-implant bone infection with low amount of bacterial loads (10(2) and 10(3) CFU of Staphylococcus aureus) and investigated osseointegration of the implants coated with hydroxyapatite (HA) and low-dosed HA-silver (HA-Ag). Non-infected implants served as controls. After 6 weeks rats were sacrificed and implants evaluated for osseointegration and infection.

RESULTS:

Infection of implanted devices was reliably induced, independently whether 10(2) or 10(3) CFU of S. aureus were inoculated and HA or HA-Ag coated implants were used. No systemic infection was present in any of the animals at the time of sacrifice, and no animal developed acute infection requiring premature sacrifice. All CFU counts of the implant and the bone at sacrifice were significantly higher than the inoculated load (p < .05). All sterilely inserted implants showed excellent osseointegration and no infection.

CONCLUSIONS:

Our present study of a rat tibia model reliably induced osteomyelitis in the metaphysis with low-doses of bacteria. The addition of low-dosed Ag to the implant coating was not able to reduce the infection rates. The results demonstrate that it is possible to develop a model of implant-related osteomyelitis in rats with low amounts of bacteria to better mimic clinical constellations. No other promoters of infection besides insertion of the screw implant were used in this model.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteomielite / Infecções Estafilocócicas / Staphylococcus aureus / Parafusos Ósseos / Modelos Animais de Doenças Tipo de estudo: Etiology_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteomielite / Infecções Estafilocócicas / Staphylococcus aureus / Parafusos Ósseos / Modelos Animais de Doenças Tipo de estudo: Etiology_studies Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article